Special Issue: Safety First: Ensuring Quality Care in the Intensely Productive EnvironmentThe HRO Model
A High Reliability Organization (HRO) repeatedly accomplishes its mission while avoiding catastrophic events, despite significant hazards, dynamic tasks, time constraints, and complex technologies. Examples include civilian and military aviation. We may improve patient safety by applying HRO concepts and strategies to the practice of anesthesiology.
| Editors Note: Since 1986 The Anesthesia Patient Safety Foundation has made great strides in its mission to assure that no patient is harmed by anesthesia. Anesthesia is now safer than ever, but much remains to be done. The next challenge for patient safety may be to mirror high reliability organizations (HROs), which are organizations that operate under high stress, high tempo, all weather conditions with an extremely low error rate of less than 1:1,000,000 (which is also referred to as six sigma reliability). The airline industry (both civilian and military) recognizes that mere 99.99% reliability is unacceptable. Such reliability would predict 1 airline accident every 20 days at a regional airport with 500 flights per day. Anesthesia, like aviation, operates in a high-tempo, high-stress, all-condition environment. This Special Issue of the APSF Newsletter will introduce critical concepts of HRO theory and practice that contain vitally important lessons for health care in general, and anesthetic practice, in particular. |
by David M. Gaba, MD
The public expects that health care, like a number of other human endeavors, should be a high reliability undertaking with little risk of preventable harm. Years ago, when medicine had few therapies to offer patients, the risks of harm due to care were low. In the current era, and increasingly over time, the processes of health care have become intrinsically hazardous, wielding powerful technologies and medications. If used improperly or in error they have the power to injure, maim, or kill. As detailed by Professor Roberts in this issue of the Newsletter (see page 13), other industries have come to grips with the routine conduct of other activities that bear intrinsic hazard. At their best, organizations in these domains have been described as High Reliability Organizations (HROs). As described by Professor Roberts, the theory of HROs has evolved over nearly 20 years.
|
Many of these industries share key features with health care that make them useful, if approximate models. These include the following:
Even more so than other industries, health care, including the perioperative setting, is not yet perfectly reliable and safe. It is difficult to measure precisely the rate of injury or death from the processes of care, and there has been considerable debate, particularly about the anesthesia-related death or injury rate. There is wide agreement that death or serious injury is a very rare event for healthy patients having routine anesthesia and surgery in accredited facilities. Yet even this very low death rate per operation is an order of magnitude higher than the fatal accident rate per departure of airliners (see www.ntsb.gov/aviation/Stats.htm). Rates of apparently preventable injury and death are much higher for sicker patients or those having more complex surgery. Of course, perioperative health care is not the same as generating electricity, flying airliners, or building a space station. For one thing, unlike nuclear power plants or airplanes, we do not design or manufacture human beings, nor do we receive an official instruction manual. Also, unlike some other industries in which the activities are relatively elective (the airliner doesnt have to fly from New York to Chicago tonight), in health care there are situations in which procedures must be performed even if the hazards are particularly high. Nonetheless, perioperative health care still has much to accomplish to qualify as a high reliability undertaking, and we have much to learn from HRO theory. |
What Specific Lessons Can We Learn From HRO Theory?
|
Although HRO Theory (HROT) is now a complex amalgam of approaches and viewpoints, some of the most relevant elements of HROT applicable to perioperative health care are discussed below. In general terms, HROT states that appropriate organizational control can yield nearly failure free results despite high hazard and high tempo, if the organization (and overall industry) embodies characteristics listed in Table 1. In the remainder of this paper these characteristics are discussed more fully as they apply to perioperative health care. Increased Standardization Needed The structures of health cares institutions and organizations may not be well-suited to achieve optimum safety or reliability. The industry is massively decentralized and poorly integrated. For example, while commercial aviation has thousands of departures per day, seemingly similar to the number of anesthetics and surgical procedures, the industry is structured very differently. Only 10 organizations (airlines) handle more than 95% of passenger miles, whereas in health care there are on the order of 6,000 hospitals owned probably by more than 1,000 firms. There is little standardizationeach organization, indeed, each work unit or each clinician has a completely different approach to common problems. Excessive or slavish reliance on standard operating procedures can be detrimental to reliability and safety. Health care of human beings clearly requires more flexibility than does flying highly uniform airliners. Still, the pendulum in health care is currently so far from the use of standard procedures that we probably have much to gain by increasing such standardization. Indeed the whole thrust of evidence-based medicine is to disseminate and standardize proven best practices. |
|
There are few economies of scale, and little integration between facilities, or between firms. Financial incentives are not aligned fully with goals of reliability and safety. The public plays a role in this misalignment, as people largely wish (irrationally) to save money on everyone else's health care, but not on their own or their familys. (This attitude is a corollary to Wildavskys Law of Medical Money.) In HROs safety and reliability are accepted as properties of the system, which needs to be resilient in the face of individual failures. Appropriate redundancies in equipment and procedures along with safety-oriented teamwork are two of the ways this can be accomplished.
Cognition, Teamwork, and Training Are Crucial
The emphasis on systems does not mean that people and their skills are unimportant. Systems are made up of people working in organizations. The dynamism, complexity, and risk in industries of high intrinsic hazard require special attention to decision making processes of individual personnel and the teams in which they work. In fact, it appears that well-functioning clinical microsystems within health care institutions may be the best current examples of HROs in health care. Such HRO-like microsystems are still found only sporadically.
The literature pertaining to cognition in dynamic team-based environments is already large and growing rapidly. Nonetheless, a few key points can be summarized here.
Simulation Ensures Readiness HROs recognize that intensive training and performance assessment in both routine work and simulation and drills pays off. HROs ensure that teams and work units hone their skills during routine operations. They debrief themselves routinely and keep track of individual and team performance. For example, every Naval aviator, regardless of experience level or seniority, is graded on every carrier landing. HROs also use simulation and drills extensively to ensure maximum readiness for critical but uncommon situations and to optimize team performance. Training is built into the work environmentit is not an add-on for the individual. The emphasis is on training the system, not just individuals. Moreover, training continues for the entirety of one's career and is not limited to those learning the job. In health care the nursing profession adheres to these principles more avidly than do physicians. Physicians rely on a fairly weak and haphazard system of continuing medical education to maintain individual abilities. This system is largely at the discretion of individuals and on their own time and expense. There is little systematic training of teams. Simulation-based training for individuals, crews, and teams in health care is just beginning. This is one of the areas in which health care can most readily adopt lessons from HROs. The APSF was a leader in bringing simulation training to health care. Already there are numerous simulation centers in which such curricula could be applied to perioperative health care teams. Organizational Learning Helps to Embed Lessons HROs aggressively pursue organizational learning about improving safety and reliability. They analyze threats and opportunities in advance. When new programs or activities are proposed they conduct special analyses of the safety implications of such programs, rather than waiting to analyze the problems that occur. Even so, problems will occur and HROs study incidents and accidents aggressively to learn critical lessons. Most importantly, HROs do not rely on individual learning of these lessons. They change the structure or procedures of the organization so that the lessons become embedded in the work. |
Unlike many HROs, health care still has very weak systems of detecting, assessing, and responding to incidents and adverse events. These are local and isolated and cannot readily share lessons learned. They typically focus on individuals not on systems, and they do not often yield practical and effective changes in work practices.
Root cause analysis and failure modes and effects analysis are techniques used by HROs that are being introduced into health care. Considerable attention has been devoted to event reporting systems. There are also projects to upgrade traditional morbidity and mortality conferences to become more systems oriented. These are important beginnings. Nonetheless, to date, there has been too much attention to issues of reporting incidents and accidents, and too little attention to the organizational learning and changes in work practices that should come from the analysis of these reports.
Safety Culture Can Offset Production Pressure
What really makes an HRO is the way that its people behave. The norms and routines of behavior based on shared values and expectations is culture (see Editors Note, at end). HROs create and maintain cultures in which safety and reliability are the most important values and norms. In this issue, Sara Singer discusses safety culture in more detail, and how health care stacks up relative to acknowledged HROs in terms of culture (see "Survey").
In health care a prime challenge to a culture of safety is production pressure, the overt or covert pressure to put production (as in throughput and efficiency) ahead of safety, despite lip service to the contrary. This has been shown to be a real problem in the operating room. All endeavors have pressure to work quickly, efficiently, and with few delays. There is an intrinsic asymmetry between production and safety such that signals about production are inherently stronger than signals about safety. Yet HROs have established mechanisms to ensure that these pressures do not overcome real safety concerns. They have evolved formal mission rules, checklists, milestones, and a system whereby even the most junior person feels empowered and obligated to halt production for a credible safety threat. Developing such mechanisms will be important for health care.
Conclusions
No organization is a perfect High Reliability Organization. Nor is health care completely devoid of structures and procedures like those of HROs. Yet medicine, which is pledged to first do no harm, is far behind other industries in adopting the organizational principles needed to strive for high reliability and safety. Many of the HRO lessons will be difficult to adopt widely. Some of the principles challenge deeply embedded aspects of the current system. Most will require the expenditure of resources to yield change and improvement. One thing is certain, however. It will likely be impossible to achieve the nearly error-free results expected by the public without heeding the lessons of High Reliability Organization Theory. Attempting to do so will just be putting Band-aids on gaping wounds.
Over the next year the APSF intends to begin a new initiative in High Reliability Perioperative Health Care. Our goal will be to help anesthesiologists and others in the perioperative setting to implement as fully as possible the lessons that can be extracted from HRO theory. Some programs may be targeted at anesthesia personnel alone. Many will need to be collaborative efforts with our surgical and nursing colleagues. We will seek to establish formal institutional links with the safety-oriented components of professional societies and organizations representing the entire spectrum of perioperative health care.
Dr. Gaba is Director of the Patient Safety Center of Inquiry at the VA Palo Alto Health Care System and Professor of Anesthesia at Stanford University School of Medicine.
Suggested Reading/General References
Editors Note: This Issue makes reference to the term Safety Culture. Experts in high reliability organization theory and practice have also introduced the term Safety Climate. While there are different implications of the two terms, for simplicity we have chosen Safety Culture to embody both concepts.