A Difficult Airway Early Warning System in Patients at Risk for Emergency Intubation: A Pilot Study

by Stephen Estime, MD; Anna Budde, MD; Avery Tung, MD

February 1, 2020

Summary: 

Managing a difficult airway during an emergency intubation outside of the operating room is associated with high morbidity and mortality1–3. We created an early warning system by incorporating airway assessment into the initial evaluation by our rapid response nursing team. During a two-month pilot period, rapid response nurses identified patients with a known or suspected difficult airway during rapid response evaluations. After two months, twenty-one patients were identified with potential difficult airways of which 62% required emergency intubation and 92% of those intubated had a difficult airway on post intubation assessment. This early warning may provide an opportunity to improve patient safety during emergency intubation.

Management of a difficult airway during an out of operating room emergency intubation is associated with high morbidity and mortality.1–5 Such patients are often unstable, and advanced airway equipment and skilled assistance are less available. Emergency airway management in the patient with an unanticipated difficult airway is particularly perilous when there is limited time to develop a plan or bring additional equipment to the bedside. Current literature suggests that difficult airway management is associated with a high incidence of desaturations, failed attempts, and difficult bag mask ventilation.1,3–5

In principle, advanced knowledge that a patient has a difficult airway should reduce the risk of emergency intubation. In such patients, a plan can be formulated in advance, multidisciplinary expertise can be arranged, equipment can be made ready, and the decision to intubate can be made earlier to reduce time pressure. However, it is not cost-effective to assess the airway of every patient in the hospital (or even in the ICU) as only a small fraction of patients will require an emergency intubation.

To improve the quality of out of operating room difficult airway management, we partnered with our rapid response nursing team to incorporate airway assessments into the rapid response evaluation. Nurses were asked to identify known difficult airway patients based on medical history and by alerts such as bracelets and electronic chart alerts. The rapid response nurses were also taught to perform an abbreviated airway exam based on the Look, Evaluate, Mallampati Score, Obstruction and Neck Mobility (LEMON) score6 that could be utilized at the time of a rapid response evaluation to identify suspected difficult airway patients (Table 1).

Table 1: Questions for identifying patients with a suspected difficult airway

1. Does the patient have limited neck range of motion (e.g., cervical collar, severe cervical neck disease)?
2. Does the patient have limited mouth opening (e.g., connective tissue disorder, jaw wiring)?
3. Does the patient grossly appear difficult (e.g., super morbid obesity, distorted facial anatomy, airway bleeding)?

Patients identified by the rapid response nurses as either known or suspected difficult airways were placed on a difficult airway “list” in the electronic medical record and their hospital course was monitored over a two-month period. We assessed for the incidence of emergency intubation and difficult intubation on post-intubation assessment. We defined a difficult airway as an intubation requiring more than two attempts of direct laryngoscopy by a senior anesthesia resident (PGY-3 and above) or attending and/or the use of adjunctive airway equipment (e.g., video laryngoscopy, fiberoptic bronchoscopy). Defining a difficult airway is variable,7,8 and we expanded the ASA’s difficult airway definition9 of a conventionally trained anesthesia professional experiencing difficulty to include a senior resident because unlike operating room intubations, residents are often the first responders during an emergency intubation outside of the operating room and difficulties with initial attempts may quickly lead to patient morbidity. Documentation of a difficult airway is often subjective and inconsistent8,9 and by including the use of adjunctive airway equipment in our definition, we aimed for more objective criteria.

Results

During the two-month pilot period, twenty-one patients were identified by rapid response nursing assessments as having a known or suspected difficult airway. Nearly 62% (13/21) required an emergency intubation during their hospitalization and 92% of those (12/13) had a difficult airway. Approximately 57% (12/21) of the known or suspected difficult airway patients were intubated emergently and had a confirmed difficult airway of which 58% (7/12) required video laryngoscopy and 42% (5/12) required fiberoptic bronchoscopy. None of the patients experienced failed airway management. One death occurred during a difficult intubation though this was in the midst of a cardiac arrest requiring chest compressions from a suspected pulmonary embolus prior to arrival of the emergency airway team.

Our data suggest that early warning of emergency intubation in known and suspected difficult airways is possible. Through strategic partnering, we created an early warning system which identified over half the patients who would require an emergency intubation and have a confirmed difficult airway. If formalized, such an early warning system has considerable potential to improve the care of inpatients who require emergency intubation in the hospital. This pilot study was limited in its a small sample size and short timeframe. Defining a difficult airway is highly variable as is the use of prophylactic video laryngoscopy and fiberoptic bronchoscopy during emergency intubations. Future work will focus on better identifying patients at high risk for emergency intubation. Ultimately, we plan to test whether advanced lead time changes how intubations are approached and whether these improve measurable patient safety outcomes.

 

Dr. Estime is an assistant professor of Anesthesia & Critical Care at the University of Chicago Medical Center.

Dr. Budde is an assistant professor of Anesthesiology at the University of Minnesota.

Dr. Tung is a professor of Anesthesia & Critical Care at the University of Chicago Medical Center. Dr. Tung also serves as the quality chief for the Department of Anesthesia and Critical Care at the University of Chicago.


Drs. Estime and Budde have no conflicts of interest to disclose. Dr. Tung serves as section editor for Critical Care & Resuscitation and Anesthesia & Analgesia.


References

  1. Scott JA, Heard SO, Zayaruzny M, et al. Airway management in critical illness: an update. Chest. November 2019. doi:10.1016/j.chest.2019.10.026.
  2. Mort TC. Complications of emergency tracheal intubation: immediate airway-related consequences: part II. J Intensive Care Med. 2007;22:208–215.
  3. Schwartz DE, Matthay MA, Cohen NH. Death and other complications of emergency airway management in critically ill adults. A prospective investigation of 297 tracheal intubations. Anesthesiology. 1995;82:367–376.
  4. De Jong A, Rolle A, Molinari N, et al. Cardiac arrest and mortality related to intubation procedure in critically ill adult patients: a multicenter cohort study. Crit Care Med. 2018;46:532–539.
  5. Joffe AM, Aziz MF, Posner KL, et al. Management of difficult tracheal intubation: a closed claims analysis. Anesthesiology. 2019;131:818–829.
  6. Reed MJ, Dunn MJG, McKeown DW. Can an airway assessment score predict difficulty at intubation in the emergency department? Emerg Med J. 2005;22:99–102.
  7. Apfelbaum JL, Hagberg CA, Caplan RA, et al. Practice guidelines for management of the difficult airway: an updated report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway. Anesthesiology. 2013;118:251–270.
  8. Bradley JA, Urman RD, Yao D. Challenging the traditional definition of a difficult intubation: what is difficult? Anesth Analg. 2019;128:584–586.
  9. Meitzen SE, Benumof JL. Video laryngoscopy: positives, negatives, and defining the difficult intubation. Anesth Analg. 2019;128:399–401.