Perioperative Brain Health and Postoperative Delirium Prevention: Recommendations from the APSF Brain Health Patient Safety Priority Advisory Group

by Ryan Field, MD; Lisa Bethea, MD; Arney Abcejo, MD; Jeffrey Huang, MD

October 1, 2025

Summary: 

The APSF Brain Health Patient Safety Priority Advisory Group highlights postoperative delirium as a leading perioperative brain health risk, emphasizing prevention through risk assessment, evidence-based interventions, and team-based strategies to improve patient outcomes.

Perioperative Brain Health and Postoperative Delirium Prevention: Recommendations from the APSF Brain Health Patient Safety Priority Advisory GroupAs we celebrate the 40th anniversary of the APSF, it is important to reflect on the growth and evolution of our specialty—specifically around the patient safety outcomes that matter most to our patients. Postoperative delirium (POD) is the most common adverse event following surgery in older adults, with an incidence as high as 65%. It is associated with prolonged hospital stay, increased morbidity and mortality, and significant distress for both patients and their families.1,2 Recognizing the critical importance of brain health, the APSF has identified it as a Patient Safety Priority. Optimizing brain health through targeted perioperative interventions is of utmost importance. In 2023, the APSF Newsletter published an article titled “Perioperative Brain Health: A Patient Safety Priority All Anesthesia Professionals Must Address,”3 which, along with the American Society of Anesthesiologists (ASA) Brain Health Initiative, has served as a foundational guide for developing brain health implementation protocols. Many hospitals have successfully created and implemented their own protocols, achieving positive outcomes.

Several evidence-based interventions have been shown to potentially reduce the risk of postoperative delirium. These include preoperative cognitive screening, early mobilization, maintaining orientation, promoting sleep hygiene, ensuring the timely return of personal items (such as glasses, hearing aids, and dentures) after surgery, intraoperative dexmedetomidine use, and providing delirium education for health care professionals.4 However, the role of intraoperative anesthetic management remains a topic of ongoing debate and controversy. Numerous new studies have emerged, some with conflicting results that may create uncertainty among anesthesia professionals regarding best practices. Consequently, the APSF Perioperative Brain Health Patient Safety Priority Advisory Group (PSPAG) believes it is essential to present these new findings to anesthesia professionals, along with updated recommendations, to facilitate effective implementation and ultimately improve patient safety and outcomes.

INTRAOPERATIVE HYPOTENSION (IOH)

Intraoperative hypotension, defined by episodes of low blood pressure during anesthesia, has been proposed as a modifiable risk factor for postoperative delirium particularly in elderly or high-risk patients.5 The brain normally maintains constant blood flow despite fluctuating systemic pressures (cerebral autoregulation), but this capacity is blunted in the elderly and those with vascular disease.5 During intraoperative hypotension, cerebral perfusion pressure falls, especially if mean arterial pressure (MAP) drops below the lower autoregulatory limits (~50–60 mmHg).5,6 Experimental and clinical evidence suggest that sustained cerebral hypoperfusion can trigger neuronal dysfunction, blood brain barrier breakdown, and neuroinflammation, all of which are implicated in delirium pathophysiology.5,6 Thus, hypotension can lead to reduced cerebral blood flow and oxygen delivery, potentially causing brain tissue injury and contributing to the development of postoperative delirium.5

Several retrospective studies5,7 suggest an association between intraoperative hypotension and postoperative delirium, but in general evidence is mixed (Table 1). A prospective randomized trial,9,12 a systematic review and meta-analysis,8 and other retrospective studies10,11 found no association between intraoperative hypotension and postoperative delirium. Overall, the evidence more strongly suggests that intraoperative hypotension may not be a primary cause of postoperative delirium.

Table 1: Studies on the Relationship Between Intraoperative Hypotension and Postoperative Delirium.

Study Type Authors / Source Population Key Findings Conclusion
Retrospective Study Wang et al.5 (2025) Elderly laryngectomy patients Sustained ≥30% MAP drop for ≥30 min → OR ≈ 1.74 (95% CI 1.04–2.91); surgery duration amplified risk IOH + prolonged surgery synergistically increases POD risk
Large Retrospective Cohort Wachtendorf et al.7 (2022) 316,717 patients (mean age >70) MAP<55 mmHg: OR ≈ 1.22 (short) to 1.57 (prolonged); +6% POD risk per 10 min MAP<55 Duration- and dose-dependent effect; absolute MAP<55 is key risk factor
Meta-analysis (RCTs) Feng et al.8 (2019) 5 RCTs comparing high vs low MAP No significant POD difference; RR ≈ 3.30 (CI 0.80–13.54), P=0.10 RCTs show non-significant trend toward harm; small sample sizes, few POD cases
Prospective Cohort Hirsch et al.9 (2015) 594 patients >65, major noncardiac No POD association with MAP<50 or 20–40% drops; BP variability was predictive BP instability, not absolute level, linked to POD
Retrospective Study Yang et al.10 (2025) 1,002 elderly hip fracture patients MAP Coefficient of Variation >10% → OR ≈ 1.45 for POD BP variability independently predicts POD
Retrospective Cohort Zarour et al.11 (2024) 2,352 elective elderly patients No POD association with MAP <65 AUC after adjustment Contradictory finding; may reflect differing IOH definitions or patient factors
Randomized controlled trial Marcucci et al.12 (2025) 2,603 patients with mean age, 70 years undergoing noncardiac surgery Intraoperative MAP>80 vs MAP >60, no difference in Montreal Cognitive Assessment (MoCA) 1 year after surgery No difference in neurocognitive outcomes between the hypotension-avoidance and hypertension-avoidance strategies
Study Type Retrospective Study
Authors / Source Wang et al.5 (2025)
Population Elderly laryngectomy patients
Key Findings Sustained ≥30% MAP drop for ≥30 min → OR ≈ 1.74 (95% CI 1.04–2.91); surgery duration amplified risk
Conclusion IOH + prolonged surgery synergistically increases POD risk
Study Type Large Retrospective Cohort
Authors / Source Wachtendorf et al.7 (2022)
Population 316,717 patients (mean age >70)
Key Findings MAP<55 mmHg: OR ≈ 1.22 (short) to 1.57 (prolonged); +6% POD risk per 10 min MAP<55
Conclusion Duration- and dose-dependent effect; absolute MAP<55 is key risk factor
Study Type Meta-analysis (RCTs)
Authors / Source Feng et al.8 (2019)
Population 5 RCTs comparing high vs low MAP
Key Findings No significant POD difference; RR ≈ 3.30 (CI 0.80–13.54), P=0.10
Conclusion RCTs show non-significant trend toward harm; small sample sizes, few POD cases
Study Type Prospective Cohort
Authors / Source Hirsch et al.9 (2015)
Population 594 patients >65, major noncardiac
Key Findings No POD association with MAP<50 or 20–40% drops; BP variability was predictive
Conclusion BP instability, not absolute level, linked to POD
Study Type Retrospective Study
Authors / Source Yang et al.10 (2025)
Population 1,002 elderly hip fracture patients
Key Findings MAP Coefficient of Variation >10% → OR ≈ 1.45 for POD
Conclusion BP variability independently predicts POD
Study Type Retrospective Cohort
Authors / Source Zarour et al.11 (2024)
Population 2,352 elective elderly patients
Key Findings No POD association with MAP <65 AUC after adjustment
Conclusion Contradictory finding; may reflect differing IOH definitions or patient factors
Study Type Randomized controlled trial
Authors / Source Marcucci et al.12 (2025)
Population 2,603 patients with mean age, 70 years undergoing noncardiac surgery
Key Findings Intraoperative MAP>80 vs MAP >60, no difference in Montreal Cognitive Assessment (MoCA) 1 year after surgery
Conclusion No difference in neurocognitive outcomes between the hypotension-avoidance and hypertension-avoidance strategies

IOH: intraoperative hypotension; POD: postoperative delirium; RCT: randomized controlled trial; CI: confidence interval; MAP: mean arterial pressure; BP: blood pressure; AUC: area under curve.

Variability in definitions (absolute vs relative hypotension) and patient populations make universal conclusions difficult. Given that intraoperative hypotension is modifiable, it remains a reasonable prevention target; guidelines now advocate vigilant blood pressure monitoring and management in older surgical patients.7 The ASA Practice Advisory for Perioperative Care of Older Adults Scheduled for Inpatient Surgery suggests individualized hemodynamic goals and rapid correction of hypotension.13 Future high-quality trials are needed to determine whether strict BP control or autoregulation-guided management reduces postoperative delirium.

Therefore, the APSF Brain Health PSPAG agrees that maintaining optimal intraoperative blood pressure, with proactive and individualized management strategies to minimize the occurrence, severity, and duration of hypotension and its associated complications in older adults is warranted.

PREOPERATIVE BENZODIAZEPINE USE

A Historical Lens on Benzodiazepines Use and Brain Health

The Beers Criteria were initially introduced to inform practitioners of medications to use with caution in nursing home residents, and these criteria were expanded to all older adults in 1997. In 2012, the American Geriatrics Society (AGS) assumed stewardship of the Criteria, introducing rigorous, evidence-based approaches to medications. These recommendations, updated in 2023, continue to place benzodiazepines on the “potentially inappropriate” list for adults over the age of 65. In the context of neuroanesthesia, brain health, and patient safety, where cognitive preservation is paramount, this caution seems well-founded. Currently, the pervasive culture around benzodiazepines in many institutions is to avoid them preoperatively.

However, it is important to recognize the limitations of the scope of the Beers Criteria. Much of the early evidence grouped benzodiazepines together: short- and long-acting agents, outpatient and inpatient medicine, one-time dose and chronic use.

Contemporary Practice Advisories and Evidence from Recent Trials

The ASA Practice Advisory for Perioperative Care of Older Adults Scheduled for Inpatient Surgery thoughtfully addressed the impact of perioperative medications with central nervous system effects on postoperative cognitive dysfunction and outcomes. The Advisory took a measured approach: “Consider the risks and benefits of medications with potential CNS effects in older adults, as these drugs may increase the risk of postoperative delirium.”13 Notably, the Advisory did not recommend avoiding short-acting benzodiazepines like midazolam or remimazolam, recognizing recent data have not demonstrated a consistent link between their use and cognitive dysfunction/delirium in older adults.

Recently, a prospective multicenter cohort study of >5,600 patients aged 65 years and older undergoing elective noncardiac procedures in China did not show an increased risk of postoperative delirium in those who received intraoperative midazolam versus those who did not (adjusted risk ratio 1.09 (95% CI, 0.91–1.22; P=0.35).14 Subgroup analyses based on age, sex, ASA class, and comorbidities revealed no population in which midazolam incurred an increased delirium risk. However, patients who received midazolam had significantly lower rates of postoperative anxiety (5.7% versus 13.4%).14

A multiperiod, double-blinded, cluster-randomized crossover trial to assess the impact of perioperative benzodiazepine use on delirium was conducted at 20 North American cardiac surgical centers (n=19,768; mean age, 65 years).15 The patients underwent cardiac surgery during either restricted (n=9,827) or liberal (n=9,941) benzodiazepine use periods. Delirium occurred in 1,373 patients (14.0%) during restricted periods and 1,485 patients (14.9%) during liberal periods (adjusted odds ratio [aOR], 0.92; 95% CI, 0.84–1.01; P=0.07). The investigators concluded that restricting benzodiazepines during cardiac surgery did not reduce the incidence of delirium.15

Pragmatic Clinical Takeaways

Altogether—between the 2025 ASA Practice Advisory and recent multicenter studies—the evidence likely does not support a recommendation to avoid single-use of short-acting benzodiazepines like midazolam in the perioperative setting in older adults.

The APSF Brain Health PSPAG agrees that in older adults:

  • Regular review of home medications and deprescribing when appropriate can reduce the risk of postoperative delirium.
  • Preoperative doses of short- (midazolam) or ultra-short acting benzodiazepines (remimazolam) need not be proscriptively avoided if specifically trying to minimize postoperative delirium.
  • Cognitive screening should still be considered to incorporate into preoperative workflows.

ANESTHESIA DEPTH AND MONITORING

For many years, the impact of monitoring and maintaining anesthetic depth with electroencephalography (EEG) monitoring on postoperative cognitive decline has been debated. The results are mixed (Table 2). The ENGAGES trial (1232 patients) found no significant reduction in delirium with EEG-guided anesthesia (26.0% vs 23.0%, P=0.22).16 In that trial, EEG guidance successfully reduced EEG burst suppression but failed to reduce the rate of delirium. Similarly, the ENGAGES-Canada trial (1140 patients) found delirium incidence of 18.15% vs 18.10% (EEG-guided vs usual care).17 A sub-study of the BALANCED trial (515 patients) reported lower delirium with lighter anesthesia (BIS 50: 19% vs BIS 35: 28%, P=0.010),18 but the full BALANCED trial (6644 patients) showed no overall benefit to targeting light vs deep anesthesia.18 The lower delirium incidence with lighter anesthesia in the BALANCED subtrial may be driven by centers with high baseline delirium, including patients with high frailty and preoperative risk factors. Furthermore, the sub-study results were mostly reflective of Asian centers, potentially highlighting the need for a population-based approach to anesthetic delivery.19

Table 2: Anesthesia Depth and Postoperative Delirium.

Study Type Authors / Source Population Key Findings Conclusion
Randomized clinical trial Wildes T et al.16 JAMA 2019 1232 patients (aged >60, undergoing major surgery and receiving general anesthesia) Postoperative delirium occurred in 26.0% of the EEG-guided anesthetic group and 23.0% of the usual care group The use of EEG-guided anesthetic administration did not prevent postoperative delirium
Multicenter randomized clinical trial Deschamps A, et al.17 JAMA 2024 1140 patients (aged >60, undergoing cardiac surgery with cardiopulmonary bypass) Delirium during postoperative days 1 to 5 occurred in 18.15% in the EEG-guided group and 18.10% in the usual care group EEG-guided anesthetic administration did not decrease the incidence of postoperative delirium
Multicenter randomized clinical trial
Delirium subgroup was retrospectively registered. The subgroup study was conducted in China
Evered LA, et al.18 BJA 2021 547 patients (aged >60, undergoing major surgery lasting 2 hr or more) The incidence of postoperative delirium in the bispectral index (BIS) 50 group was 19% and in the BIS 35 group was 28% (P=0.010) Targeting light anesthesia reduced the risk of postoperative delirium.
Study Type Randomized clinical trial
Authors / Source Wildes T et al.16 JAMA 2019
Population 1232 patients (aged >60, undergoing major surgery and receiving general anesthesia)
Key Findings Postoperative delirium occurred in 26.0% of the EEG-guided anesthetic group and 23.0% of the usual care group
Conclusion The use of EEG-guided anesthetic administration did not prevent postoperative delirium
Study Type Multicenter randomized clinical trial
Authors / Source Deschamps A, et al.17 JAMA 2024
Population 1140 patients (aged >60, undergoing cardiac surgery with cardiopulmonary bypass)
Key Findings Delirium during postoperative days 1 to 5 occurred in 18.15% in the EEG-guided group and 18.10% in the usual care group
Conclusion EEG-guided anesthetic administration did not decrease the incidence of postoperative delirium
Study Type Multicenter randomized clinical trial
Delirium subgroup was retrospectively registered. The subgroup study was conducted in China
Authors / Source Evered LA, et al.18 BJA 2021
Population 547 patients (aged >60, undergoing major surgery lasting 2 hr or more)
Key Findings The incidence of postoperative delirium in the bispectral index (BIS) 50 group was 19% and in the BIS 35 group was 28% (P=0.010)
Conclusion Targeting light anesthesia reduced the risk of postoperative delirium.

EEG: electroencephalography; BIS: bispectral index.

However, the benefits of intraoperative EEG monitoring were demonstrated in a randomized clinical trial of 177 pediatric patients in which EEG-guided titration of anesthesia was compared with standard 1.0-MAC sevoflurane anesthesia. EEG-guided management of general anesthesia reduced the incidence of pediatric emergence delirium (35% vs 21%), while also resulting in faster emergence and shorter postanesthesia care unit stays.20 While promising, these findings may not directly translate to adult populations given the differing pathophysiology and types of delirium.

The evidence from studies in adult patients suggests the use of EEG-guided anesthetic administration for the prevention of postoperative delirium did not decrease the incidence of postoperative delirium or yield significantly superior outcomes in patients receiving volatile-agent-based general anesthesia. Burst suppression can be visually identified in raw EEG recordings, yet its association with postoperative delirium remains unclear. Most studies rely on commercial monitoring technologies that estimate burst suppression using processed EEG values, which typically underestimate its extent. Some experts suggest that raw EEG-guided intraoperative drug titration may offer a more accurate and effective approach to detect and prevent burst suppression.21 Future clinical trials are needed.

The APSF Brain Health PSPAG agrees that in older adults:

  1. Intraoperative EEG monitoring is a useful adjunct to tailor anesthetic depth and support precision anesthesia by individualizing care, where it may help minimize drug exposure.
  2. The evidence on intraoperative EEG monitoring and prevention of postoperative delirium is inconclusive.

ANESTHESIA TECHNIQUES

Alongside depth, the choice of anesthetic (general vs regional) has been debated. A recent meta-analysis (21 trials, >1.7 million patients)22 found that delirium was not significantly different between general anesthesia and regional anesthesia groups once confounders were controlled.22 The RAGA trial (950 patients) found similar delirium rates with regional anesthesia without sedation (6.2%) vs general anesthesia (5.1%), a nonsignificant difference.23 Using regional techniques alone did not reduce postoperative delirium. A recent meta-analysis encompassing 10 randomized controlled trials with a total of 3,968 elderly patients undergoing hip fracture surgery found no significant difference in the incidence of postoperative delirium between neuraxial anesthesia and general anesthesia.24 The authors concluded choice of anesthesia technique alone does not significantly influence postoperative delirium risk in this patient population. Interestingly, a small study (n=114) of elderly patients undergoing hip fracture surgery under spinal anesthesia, reported that light propofol sedation (BIS ≥80) halved delirium incidence compared to deep sedation (19% vs 40%, P=0.02).25 Avoiding excessive sedation may be a key strategy. Future work is needed to identify subgroups and confounding variables that explain conflicting results and help us learn how to selectively apply these interventions.

Current evidence indicates that there are no significant differences in the incidence of postoperative delirium or other delirium-related outcomes between the regional anesthesia and general anesthesia groups.

The APSF Brain Health PSPAG agrees that in older adults (Table 3):

  1. Selection of anesthesia techniques does not significantly affect the incidence of postoperative delirium.

Table 3: Summary of APSF Brain Health PSPAG Recommendations.

Clinical Category APSF Brain Health PSPAG Recommendations
Preoperative Benzodiazepine Use Preoperative doses of short- (midazolam) or ultra-short acting benzodiazepines (remimazolam) need not be proscriptively avoided if specifically trying to minimize postoperative delirium in older adults.
Intraoperative Hypotension Maintaining optimal intraoperative blood pressure is recommended, with proactive and individualized management strategies to minimize the occurrence, duration, and severity of hypotension and its associated complications in older adults.
Anesthesia Depth And Monitoring Currently, the data on intraoperative EEG monitoring and the prevention of postoperative delirium in older adults is inconclusive.
Anesthesia Techniques Selection of anesthesia techniques (GA or RA) does not significantly affect the incidence of postoperative delirium in older adults.

EEG: electroencephalography; GA: general anesthesia; RA: regional anesthesia.

CONCLUSION

Current evidence suggests that intraoperative hypotension is unlikely to be a primary driver of postoperative delirium. However, maintaining optimal intraoperative blood pressure remains important to minimize related complications, particularly in older adults. The use of short-acting (e.g., midazolam) or ultra-short-acting benzodiazepines (e.g., remimazolam) in the preoperative period does not need to be categorically avoided solely to reduce the risk of postoperative delirium. The data on intraoperative EEG monitoring and delirium prevention is inconclusive. Furthermore, the choice of anesthetic technique—whether general or regional anesthesia—does not appear to significantly impact the incidence of postoperative delirium. As brain health research continues to evolve globally, it is essential to regularly update clinical guidelines based on emerging evidence, and all recommendations should be interpreted in the context of ongoing developments.

 

Ryan Field, MD, is co-chair of the APSF Brain Health PSPAG, and professor, Department of Anesthesiology, UC Irvine Health, Orange, CA.

Lisa Bethea, MD, is assistant member, Department of Anesthesiology & Critical Care, Moffitt Cancer Center, Tampa, FL.

Arney Abcejo, MD, is associate professor of anesthesiology, Department of Anesthesiology and Perioperative Medicine, Mayo Clinic, Rochester, MN.

Jeffrey Huang, MD, is co-chair of the APSF Brain Health PSPAG; senior member, Department of Anesthesiology & Critical Care, Moffitt Cancer Center; professor of oncological science, University of South Florida Morsani College of Medicine, Tampa, FL.


The authors report no conflicts of interest.


Acknowledgment: We gratefully acknowledge Val Rangasamy, Sara Honardoost, TJ Gan, Lena Scotto, Abbas Al-Qamari, Steven Barker, and Michael Mestek for reviewing earlier drafts of this article, offering constructive criticism, and helping shape the final manuscript with their insightful perspectives.


REFERENCES

  1. Peden CJ, Miller TR, Deiner SG, et al. Improving perioperative brain health: an expert consensus review of key actions for the perioperative care team. Br J Anaesth. 2021;126:423–432. PMID: 33413977.
  2. Partridge JSL, Crichton S, Biswell E, et al. Measuring the dis- tress related to delirium in older surgical patients and their relatives. Int J Geriatr Psychiatry. 2019;34:1070–1077. PMID: 30945343.
  3. Moreland NC, Scotto L, Abcejo AS. Methangkool E. Perioperative brain health: a patient safety priority all anesthesia professionals must address. APSF Newsletter. 2023; 38:2,34,36–38. https://www.apsf.org/news-updates/the-patient-safety-movement-foundation-and-anesthesia-patient-safety-foundation-award-the-patient-safety-curriculum-award/ Accessed August 10, 2025.
  4. Aldecoa C, Bettelli G, Bilotta F, et al. Update of the European Society of Anaesthesiology and Intensive Care Medicine evidence-based and consensus-based guideline on postoperative delirium in adult patients. Eur J Anaesthesiol. 2024;41:81–108. PMID: 37599617.
  5. Wang Y, Chen K, Ye M, Shen X. Intraoperative hypotension and postoperative delirium in elderly male patients undergoing laryngectomy: a single-center retrospective cohort study. Braz J Anesthesiol. 2024;75:844560. PMID: 39277101.
  6. Qureshi O, Arthur ME. Recent advances in predicting, preventing, and managing postoperative delirium. Fac Rev. 2023;12:19. PMID: 37529149.
  7. Wachtendorf LJ, Azimaraghi O, Santer P, et al. Association between intraoperative arterial hypotension and postoperative delirium after noncardiac surgery: a retrospective multicenter cohort study. Anesth Analg. 2022;134:822–833. PMID: 34517389.
  8. Feng X, Hu J, Hua F, et al. The correlation of intraoperative hypotension and postoperative cognitive impairment: a meta-analysis of randomized controlled trials. BMC Anesthesiol. 2020;20:193. PMID: 32758153.
  9. Hirsch J, DePalma G, Tsai TT, et al. Impact of intraoperative hypotension and blood pressure fluctuations on early postoperative delirium after non-cardiac surgery. Br J Anaesth. 2015;115:418–426. PMID: 25616677.
  10. Yang P, Fan Y, Tang W. Correlation of intraoperative blood pressure variability and postoperative delirium in elderly hip fracture surgery. Sci Rep. 2025;15:15007. PMID: 40301442.
  11. Zarour S, Weiss Y, Abu-Ghanim M, et al. Association between intraoperative hypotension and postoperative delirium: a retrospective cohort analysis. Anesthesiology. 2024;141:707–718. PMID: 38995701.
  12. Marcucci M, Chan MTV, Painter TW, et al. cogPOISE-3 Trial Investigators and Study Groups. Effects of a hypotension-avoidance versus a hypertension-avoidance strategy on neurocognitive outcomes after noncardiac surgery. Ann Intern Med. 2025;178:909–920. PMID: 40456161.
  13. Sieber F, McIsaac DI, Deiner S, et al. 2025 American Society of Anesthesiologists practice advisory for perioperative care of older adults scheduled for inpatient surgery. Anesthesiology. 2025;142:22–51. PMID: 39655991.
  14. Li H, Liu C, Yang Y, et al. Effect of intraoperative midazolam on postoperative delirium in older surgical patients: a prospective, multicenter cohort study. Anesthesiology. 2025;142:268–277. PMID: 39470760.
  15. Spence J, Devereaux PJ, Lee SF, et al. B-Free Investigators and the Canadian Perioperative Anesthesia Clinical Trials Group. Benzodiazepine-free cardiac anesthesia for reduction of postoperative delirium: a cluster randomized crossover trial. JAMA Surg. 2025;160:286–294. PMID: 39878960.
  16. Wildes TS, Mickle AM, Ben Abdallah A, et al. ENGAGES Research Group. Effect of electroencephalography-guided anesthetic administration on postoperative delirium among older adults undergoing major surgery: the ENGAGES Randomized Clinical Trial. JAMA. 2019;321:473–483. PMID: 30721296.
  17. Deschamps A, Ben Abdallah A, Jacobsohn E, et al. Canadian Perioperative Anesthesia Clinical Trials Group. Electroencephalography-guided anesthesia and delirium in older adults after cardiac surgery: The ENGAGES-Canada Randomized Clinical Trial. JAMA. 2024;332:112–123. PMID: 38857019.
  18. Evered LA, Chan MTV, Han R, et al. Anaesthetic depth and delirium after major surgery: a randomised clinical trial. Br J Anaesth. 2021;127:704–712. PMID: 34465469.
  19. Miyasaka KW, Suzuki Y, Brown EN, Nagasaka Y. EEG-guided titration of sevoflurane and pediatric anesthesia emergence delirium: a randomized clinical trial. JAMA Pediatr. 2025;179:704–712. PMID: 40257811.
  20. Whitlock EL, Gross ER, King CR, Avidan MS. Anaesthetic depth and delirium: a challenging balancing act. Br J Anaesth. 2021;127:667–671. PMID: 34503835.
  21. Pawar N, Barreto Chang OL. Burst suppression during general anesthesia and postoperative outcomes: mini review. Front Syst Neurosci. 2022;15:767489. PMID: 35069132.
  22. Zhu X, Yang M, Mu J, et al. The effect of general anesthesia vs. regional anesthesia on postoperative delirium—a systematic review and meta-analysis. Front Med (Lausanne). 2022;9:844371. PMID: 35419373.
  23. Li T, Li J, Yuan L, et al. Effect of regional vs general anesthesia on incidence of postoperative delirium in older patients undergoing hip fracture surgery: the RAGA Randomized Trial. JAMA. 2022;327:50–58. PMID: 34928310.
  24. Cheung KY, Yang TX, Chong DY, So EH. Neuraxial versus general anesthesia in elderly patients undergoing hip fracture surgery and the incidence of postoperative delirium: a systematic review and stratified meta-analysis. BMC Anesthesiol. 2023;23:250. PMID: 37481517.
  25. Sieber FE, Zakriya KJ, Gottschalk A, et al. Sedation depth during spinal anesthesia and the development of postoperative delirium in elderly patients undergoing hip fracture repair. Mayo Clin Proc. 2010;85:18–26. PMID: 20042557.