Episode #289 Forty Years Of Anesthesia Medication Safety: What Works And What’s Next
January 14, 2026Welcome to the next installment of the Anesthesia Patient Safety podcast hosted by Alli Bechtel. This podcast will be an exciting journey towards improved anesthesia patient safety.
Our featured article again today is from the October 2025 APSF Newsletter. It is “APSF’s Forty-Year Commitment to Medication Safety in Anesthesia” by Aubrey Samost-Williams, MD, MS; Jeffrey Cooper, PhD; Arney Abcejo, MD; Elizabeth Rebello, MD, FASA, FACHE
Thank you so much to Elizabeth Rebello for contributing to the show today.

Figure 1: Comparison of the inpatient medication administration process and the OR medication administration process. Timing estimated from Bhansali and colleagues,7 Yen and colleagues,8 and internal pharmacy data.
Here are the links to the APSF articles and initiatives that we talked about on the show today:
https://www.apsf.org/look-alike-drugs/
Here is the recent announcement from the APSF and the ISMP, “Preventing Wrong Drug-Wrong Route Errors Involving Tranexamic Acid and Local Anesthetics” that was published online in November 2025. You can check it out here.
The FDA increased awareness about this potentially fatal patient safety threat by issuing the following changes to the tranexamic acid prescribing information:
- Added a Boxed Warning to communicate the risk of medication errors involving inadvertent neuraxial administration of tranexamic acid injection
- Added a statement to indicate that tranexamic acid injection is contraindicated as a neuraxial injection
- Updated the Dosage and Administration section to clarify that tranexamic acid injection is only to be administered intravenously and to provide instructions for preparing and administering the diluted solution
The FDA also recommends that the container labels for tranexamic acid injection prominently display the product name and IV route of administration. Here is the FDA Tranexamic Acid prescribing information update:
This episode was edited and produced by Mike Chan.
Subscribe to our YouTube Channel here: https://www.youtube.com/@AnesthesiaPatientSafety
Be sure to check out the APSF website at https://www.apsf.org/
Make sure that you subscribe to our newsletter at https://www.apsf.org/subscribe/
Follow us on Twitter @APSForg
Questions or Comments? Email me at podcast@apsf.org.
Thank you to our individual supports https://www.apsf.org/product/donation-individual/
Be a part of our first crowdfunding campaign https://www.apsf.org/product/crowdfunding-donation/
Thank you to our corporate supporters https://www.apsf.org/donate/corporate-and-community-donors/
Additional sound effects from: Zapsplat.
© 2026, The Anesthesia Patient Safety Foundation
Hello and welcome back to the Anesthesia Patient Safety Podcast. My name is Alli Bechtel, and I am your host. Thank you for joining us for another show. We are still celebrating the New Year here on the podcast with the exciting conclusion to our two-part series on Medication Safety that we started last week. Last week, we talked about the history of the APSF’s work to improve medication safety during anesthesia care. There is still more work to be done so let’s keep the conversation going.
Before we dive further into the episode today, we’d like to recognize Vertex, a major corporate supporter of APSF. Vertex has generously provided unrestricted support to further our vision that “no one shall be harmed by anesthesia care”. Thank you, Vertex – we wouldn’t be able to do all that we do without you!”
Our featured article once again today is “APSF’s Forty-Year Commitment to Medication Safety in Anesthesia” by Aubrey Samost-Williams and colleagues. To follow along with us, head over to APSF.org and click on the Newsletter heading. First one down is the current issue. From there, scroll down to our featured article today. I will include a link in the show notes as well.
Medication Safety is one of the APSF’s Patient Safety Priorities and it has been a priority since the APSF was founded in 1985. Last week, we talked about the challenge of medication safety in the operating room since it may just be the sole anesthesia professional who is responsible for selecting the medication and dose, preparing the medication, and administering the medication. This is a unique challenge for anesthesia professionals. Other places in the hospitals have 3 different groups of people performing these tasks and this adds in a couple layers of safety checks. We also talked about recommendations from the 2010 and 2018 APSF Stoelting Conference on medication safety as well as APSF Medication Safety initiatives.
Now, it’s time to get back into the article. Let’s check out the work that the APSF has done between 2018 and the 2024 APSF Stoelting Conference. There are some exciting initiatives that you may be familiar with because we have talked about them before on the podcast. First up, the Look-Alike Drug Vials Gallery was created in 2018. This resource has helped the APSF develop further industry partnerships to address the challenge of look-alike vials. We hope that you will check it out. Head over to apsf.org and click on the patient safety resources heading. First one down is initiatives and then the first drop down is the Look-Alike Drug Vials Gallery. I will include the link in the show notes as well. The alerts and photos in the gallery show how look-alike drug vials and packaging can contribute to medication errors and impact patient safety. The latest alert is from December 22, 2025 and includes pictures of multiple different appearing versions of commonly used drugs in an anesthesia drug cabinet: ondansetron (3), metoclopramide (2), dexamethasone (2). We hope that you will check out the gallery and consider submitting a Look Alike Drug Alert the next time you come across look alike medications in your anesthesia practice.
Next, we have the APSF Patient Safety Advisory Groups which were formed in 2021 and includes a mediation safety group. Members of this group include anesthesiologists, certified registered nurse anesthetists, anesthesiologist assistants, anesthesiology residents, pharmacists, perioperative nurses, a lawyer specializing in medical malpractice, and industry partners representing pharmaceutical and device companies. The group is working on implementing recommendations from the 2024 Stoelting Conference.
Important work has been done by the APSF on medication errors involving intrathecal administration of tranexamic acid or TXA. You can check out the June 2024 APSF Newsletter article, “Unraveling a Recurrent Wrong Drug-Wrong Route Error—Tranexamic Acid in Place of Bupivacaine: A Multistakeholder Approach to Addressing this Important Patient Safety Issue” or listen to Episode #209 of this podcast for more information about this serious medication error. By working with industry partners, the APSF has promoted the availability of TXA in infusion bags and reduced the use of TXA in vials in the perioperative environment. Has your hospital made the switch to infusion bags of TXA? If not, have you removed TXA vials from the operating rooms? These changes can make a big difference for improving medication safety.
More work was done by the APSF in 2024 together with the Institute for Safe Medication Practices, the ISMP, to investigate reports of coring of vial tops when preparing medications for administration. Check out the March 2025 alert for anesthesia professionals in the US, “Patient Safety Alert: Urgent Alert Regarding Medication Vial Coring and Fragmentation Risks” and I will include a link in the show notes.
One more example involves the advocacy by the APSF for the re-instatement of the American Society for Testing and Materials Standard D4774 which standardizes the color-coding used on labels for different medication classes. This is important work by the APSF for these industry-wide standards to make sure that concerns from practicing anaesthesia professionals are incorporated into the equipment that we work with every day in the OR.
And now it’s time to talk about the most recent APSF Stoelting Conference on Medication Errors and Opioid Safety from 2024. This time there was an additional focus on the harms of opioids in the immediate postoperative period and beyond and considerations for multimodal pain management and the role for safe opioid use. Technology has also come along way with the rise of artificial intelligence and this may make a big difference for preventing medication errors in the future with clinical decision support tools that can help determine whether the medication to be administered is a good choice given the patient’s current physiologic state. There are also new challenges and safety risks that we need to consider as well.
This conference also highlighted that many of the medication safety challenges have not changed in the past 40 years. We are still seeing basic syringe swaps and medication dosing errors due to differing concentrations. The two earlier Stoelting Conferences recommended work on human factors and system safety principles. We now know how important it is to improve these processes and identify best practices for medication safety, but there is a big gap when it comes to implementation. You are probably aware of this gap in your anaesthesia practice. In a pre-conference poll prior to the 2024 Stoelting Conference, attendees reported that fewer than half of their institutions had fully implemented practices such as standardized drug labelling, prefilled syringes for at least 3 unique medications, or standardized medication drawers for automated dispensing cabinets or medications trays. And this is from a group that was self-selected for interest and leadership in medication safety. Going forward, we would like to see top standardization strategies that include syringe label design, color-coded syringe labels, standardized concentrations, prefilled syringes, and standardized medication storage locations during surgery. Another goal to help prevent opioid-related harm including appropriate preoperative assessments, postoperative monitoring, and research into nonopioid alternatives. We know what we need to do to improve medication safety. The next step is to pivot to implementation science to better identify barriers and help institutions successful implement measures that we know can save lives.
We have come a long way over the past 40 years when it comes to medication administration and we are excited where the next 40 years will take us. Our crystal ball reveals that we will need to incorporate human factors, cutting edge technology, systems engineering, and implementation science together with increased collaboration between pharmacists, nurses, institutional leadership, industry, safety organizations, standard-setting organizations, and federal agencies.
[Bechtel] Before we wrap up for today, we are going to hear from Elizabeth again. I also asked her what she envisions for the future when it comes to medication safety. Here is her response.
[Rebello] “ Medication safety, implementation science is the next leap. We know what works. Standardized concentrations and labeling, prefilled syringes, organized storage, barcode-based identification, and robust documentation. Yet adoption still lags. The future is closing that gap reliably across institutions. Add to that smarter clinical decision support, continuous learning from near misses and stronger partnerships with industry and the FDA safer systems everywhere will provide a promising future.”
[Bechtel] Elizabeth also shared what she hopes to see going forward. Let’s take a listen now.
[Rebello] I hope to see universal basics, color coded, readable syringe labels, standardized drug carts, and a DC drawers, elimination of concentrated agents in the OR and routine pharmacy prepared or prefilled syringes. I’d like to also open reporting cultures when these elements are in place. The workload shifts freeing the anesthesia professional to focus on the patient in front of them.
[Bechtel] Thank you so much to Elizabeth for contributing to our show today and for your work on medication safety. We are looking forward to a future with implementation of these medication safety recommendations so that we can focus on the patient in front of us!
And speaking of medication safety, have you seen the recent announcement from the APSF and the ISMP, “Preventing Wrong Drug-Wrong Route Errors Involving Tranexamic Acid and Local Anesthetics?” This was published online in November 2025. To follow along, head over to APSF.org and click on the Patient Safety Resources Heading. The 5th one down is News and Updates and then scroll down until you see our featured article. We have talked about this dangerous wrong drug, wrong route medication error where intravenous tranexamic acid has been inadvertently administered into the intrathecal space in place of location anesthetics such as Bupivacaine and Ropivacaine. The mortality following these events may be 50% with survivors often left with permanent neurological harm. The FDA has recently increased awareness about this potentially fatal patient safety threat by issuing the following changes to the tranexamic acid prescribing information:
- Added a Boxed Warning to communicate the risk of medication errors involving inadvertent neuraxial administration of tranexamic acid injection
- Added a statement to indicate that tranexamic acid injection is contraindicated as a neuraxial injection
- Updated the Dosage and Administration section to clarify that tranexamic acid injection is only to be administered intravenously and to provide instructions for preparing and administering the diluted solution
The FDA also recommends that the container labels for tranexamic acid injection prominently display the product name and IV route of administration. I will include a link to the FDA information in the show notes.
When it comes to this medication error, let’s review the key safety concerns.
- Tranexamic acid and local anaesthetics are frequently stocked in similar packaging (vials/ampules) and storage locations, creating a high risk for look-alike drug mix-ups.
- Both of these medications are commonly used during the same types of surgery, with the majority of catastrophic wrong drug-wrong route errors occurring during orthopaedic arthroplasty and other procedures.
- These drugs are often stocked in areas where barcode scanning is not routinely utilized (e.g., perioperative areas, labour and delivery, emergency department), thus mix-ups are less likely to be detected.
- Intrathecal administration of tranexamic acid is a “never event” that has caused seizures, paraplegia, cardiovascular collapse, and death.
- Traditional safeguards such as education and double checks are insufficient on their own; higher-leverage system strategies and safeguards must be adopted.
We hope that everyone listening assumes that this may be a risk within your organization. Don’t wait until an event occurs to take action. And here are the joint recommendations from the APSF and ISMP so that you can take action right now to keep patients safe and prevent tranexamic acid and local anaesthetic mix-ups.
- Removal of Tranexamic acid Vials/Ampules from Perioperative Areas
- Only ready-to-administer tranexamic acid premixed IV bags (1,000 mg per 100 mL) from manufacturers, compounding pharmacies, or institutional pharmacies should be stocked and available in the perioperative environment.
- Healthcare organizations should meet with key stakeholders (e.g., anesthesiologists, certified registered nurse anesthetists [CRNAs], certified anesthesiologist assistants [CAAs], surgeons, surgical staff, pharmacists) to review their workflow when ordering and administering tranexamic acid injection to understand usage (e.g., indication, dose, concentration, route). Seek agreement with stakeholders to eliminate the availability of multiple concentrations and work toward a standard concentration.
- Some off-label uses may occur in specific circumstances that require a vial, such as preparing soaked gauze. In these cases, appropriate alternative safety measures should be identified and implemented. When the 100 mg/mL tranexamic acid injection vial or ampule is being used in an off-label manner, consider completing a failure mode and effects analysis (FMEA) to identify potential failure modes and mitigation strategies, such as restricting access.
- Implementation of High-Leverage System Safeguards
- Use barcode scanning or other technology-assisted machine-readable code at the point of care for verification before administration.
- Employ forcing functions and fail-safes, such as NRFit™ connectors for use with medications appropriate for neuraxial administration, to prevent wrong route delivery of medications.
- Standardize workflows to minimize the need for practitioner-prepared syringes.
- Institutional and Regulatory Support
- Hospital and health system leaders must support medication safety by prioritizing the elimination of unsafe drug presentations and ensuring access to commercially available premixed infusion bags or standardized pharmacy-prepared alternatives.
- Regulatory agencies, accrediting bodies, and manufacturers should align to require safer packaging and distribution practices for tranexamic acid.
- Fostering a Culture of Safety
- Gather feedback from practitioners and establish non-punitive reporting systems for near-miss and error events. Report incidents internally, to FDA MedWatch, and ISMP.
- Provide peer support for practitioners involved in adverse events.
- Regularly review system vulnerabilities and medication safety data with key stakeholders.
Tranexamic acid is an effective medication that improves outcomes in surgical and obstetric patients when used correctly. The risk is unacceptably high for a catastrophic wrong drug-wrong route error when tranexamic acid in vials and ampules remains available in the perioperative setting. So, what are you waiting for? The time to act is now to eliminate tranexamic acid vials and ampules from the perioperative environment and transition to ready-to-administer products supported by robust system safeguards.
If you have any questions or comments from today’s show, please email us at podcast@apsf.org. Please keep in mind that the information in this show is provided for informational purposes only and does not constitute medical or legal advice. We hope that you will visit APSF.org for detailed information and check out the show notes for links to all the topics we discussed today.
Until next time, stay vigilant so that no one shall be harmed by anesthesia care.
© 2026, The Anesthesia Patient Safety Foundation