- The systematic review focuses on patients with aortic stenosis (AS) who received neural axial anesthesia (NA) during surgery. The study aims to assess the safety of anesthesia, specifically for the aging population with AS undergoing surgery. PubMed, Embase, and Web of Science were searched for relevant studies until May 10, 2023.
- A total of 3228 patients were included in the study, categorized into noncardiac (3146), obstetric (69), and cardiac (13) procedures. Spinal blocks were the most common type of NA (87.2%), followed by epidural anesthesia (12%), and combined spinal-epidural anesthesia (0.8%). Primary outcomes focused on intraoperative and postoperative complications.
- The most common complication was hypotension requiring vasopressors, with rates of 9.9% for noncardiac, 13.0% for obstetric, and 7.7% for cardiac procedures. Severity of AS and optimal medical dosage for NA were unclear, and there were no reported cases of cardiovascular collapse or mortality.
- Postoperatively, adverse events were reported in 16.1% for noncardiac, 30.4% for obstetric, and 0% for cardiac procedures. Blood transfusion and bleeding were the most common complications for noncardiac and obstetric procedures. Overall 30-day mortality for patients with AS undergoing all procedures was 0.74%.
- The conclusion suggests that, with appropriate patient selection, performing NA may not be an absolute contraindication for those with AS. Future prospective studies, including patients with AS undergoing NA and general anesthesia, are recommended.
Summary of "Neuraxial Anesthesia in Patients With Aortic Stenosis: A Systematic Review"
Summary published March 18, 2024