Summary of "Inpatient Postoperative Mortality: Comparing Patients Hospitalized Preoperatively to Those Having Elective Surgery"

Summary published February 2, 2026

Summary by John "J.W." Beard, MD MBA

Anesthesiology | July 2025

Epstein RH, Dexter F, Fahy BG. Inpatient Postoperative Mortality: Comparing Patients Hospitalized Preoperatively to Those Having Elective Surgery. Anesthesiology. 2025 Jul 1;143(1):62-70. doi: 10.1097/ALN.0000000000005477. Epub 2025 Mar 27. PMID: 40146929.

doi: https://doi.org/10.1097/aln.0000000000005477

  • Perioperative mortality is often cited as a leading cause of death worldwide, but this statistic overlooks the distinction between patients undergoing scheduled “elective” surgeries and patients undergoing emergent, urgent, or otherwise “nonelective” surgeries.
  • This study addressed postoperative mortality and whether most perioperative deaths occur after elective or nonelective (urgent/emergent or inpatient) surgery. The authors sought to clarify where the greatest burden of postoperative mortality lies and to better target patient safety interventions.
  • The authors conducted a retrospective analysis on all adult patients undergoing major surgery in Florida (2021–2022) who were hospitalized for at least two nights.
  • Surgeries were classified as elective or nonelective. Surgeries were classified as elective if they occurred on the day of admission without the patient having received treatment in the ED; otherwise, they were classified as nonelective.
  • 1,245,537 surgical hospitalizations were included in the study. Of these, 70% were for nonelective surgery.
  • 95% of in-hospital deaths occurred in the nonelective surgery group.
  • The in-hospital mortality rate was 2.3% for nonelective surgery and 0.3% for elective surgery.
  • Nonelective patients also had higher rates of major complications, including acute kidney injury, hospital acquired pneumonia, major adverse cardiovascular events, and infection.
  • The authors concluded that most perioperative deaths occur in patients already hospitalized or requiring urgent surgery, not in those undergoing scheduled elective procedures.
  • For anesthesia professionals, these results suggest that efforts to reduce perioperative mortality should focus on optimizing care for inpatients and those undergoing nonelective surgery—such as improved preoperative management of acute conditions and more intensive postoperative monitoring—rather than on elective surgical patients.
  • The study also highlights the limited impact that further reducing mortality in elective cases would have on overall perioperative mortality rates.