{"id":60715,"date":"2020-03-22T11:00:13","date_gmt":"2020-03-22T16:00:13","guid":{"rendered":"https:\/\/www.apsf.org\/?p=60715"},"modified":"2020-05-08T01:14:07","modified_gmt":"2020-05-08T06:14:07","slug":"covid-19-%e7%96%ab%e6%83%85%e6%9c%9f%e9%97%b4%e9%ba%bb%e9%86%89%e4%b8%93%e4%b8%9a%e4%ba%ba%e5%a3%ab%e9%98%b2%e6%8a%a4%e8%a3%85%e5%a4%87%e7%9a%84%e4%bd%bf%e7%94%a8","status":"publish","type":"post","link":"https:\/\/www.apsf.org\/zh-hans\/news-updates\/covid-19-%e7%96%ab%e6%83%85%e6%9c%9f%e9%97%b4%e9%ba%bb%e9%86%89%e4%b8%93%e4%b8%9a%e4%ba%ba%e5%a3%ab%e9%98%b2%e6%8a%a4%e8%a3%85%e5%a4%87%e7%9a%84%e4%bd%bf%e7%94%a8\/","title":{"rendered":"COVID-19 \u75ab\u60c5\u671f\u95f4\u9ebb\u9189\u4e13\u4e1a\u4eba\u58eb\u9632\u62a4\u88c5\u5907\u7684\u4f7f\u7528"},"content":{"rendered":"<p><div class=\"imgwrapperright\" \/><p><a href=\"https:\/\/www.asahq.org\" target=\"_blank\" rel=\"noopener noreferrer\"><img decoding=\"async\" class=\"alignnone wp-image-16725\" src=\"https:\/\/www.apsf.org\/wp-content\/uploads\/collateral\/corporate-logos\/asa-logo-2018-300x73.png\" alt=\"\u7f8e\u56fd\u9ebb\u9189\u533b\u5e08\u534f\u4f1a (ASA)\" width=\"250\" height=\"61\" srcset=\"https:\/\/www.apsf.org\/wp-content\/uploads\/collateral\/corporate-logos\/asa-logo-2018-300x73.png 300w, https:\/\/www.apsf.org\/wp-content\/uploads\/collateral\/corporate-logos\/asa-logo-2018-200x49.png 200w, https:\/\/www.apsf.org\/wp-content\/uploads\/collateral\/corporate-logos\/asa-logo-2018-768x188.png 768w, https:\/\/www.apsf.org\/wp-content\/uploads\/collateral\/corporate-logos\/asa-logo-2018.png 805w\" sizes=\"(max-width: 250px) 100vw, 250px\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/www.apsf.org\"><img decoding=\"async\" class=\"alignnone wp-image-12621\" src=\"https:\/\/www.apsf.org\/wp-content\/uploads\/collateral\/apsf-logos\/APSF-Logo-297x100.png\" alt=\"\u9ebb\u9189\u60a3\u8005\u5b89\u5168\u57fa\u91d1\u4f1a (APSF)\" width=\"250\" height=\"84\" srcset=\"https:\/\/www.apsf.org\/wp-content\/uploads\/collateral\/apsf-logos\/APSF-Logo-297x100.png 297w, https:\/\/www.apsf.org\/wp-content\/uploads\/collateral\/apsf-logos\/APSF-Logo-297x100-200x67.png 200w\" sizes=\"(max-width: 250px) 100vw, 250px\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/www.anesthetist.org\/\" target=\"_blank\" rel=\"noopener noreferrer\"><img decoding=\"async\" class=\"alignnone wp-image-45477\" src=\"https:\/\/www.apsf.org\/wp-content\/uploads\/collateral\/corporate-logos\/aaaa-logo-300x128.png\" alt=\"\u7f8e\u56fd\u9ebb\u9189\u533b\u5e08\u52a9\u7406\u5b66\u4f1a (AAAA)\" width=\"250\" height=\"107\" srcset=\"https:\/\/www.apsf.org\/wp-content\/uploads\/collateral\/corporate-logos\/aaaa-logo-300x128.png 300w, https:\/\/www.apsf.org\/wp-content\/uploads\/collateral\/corporate-logos\/aaaa-logo-200x85.png 200w, https:\/\/www.apsf.org\/wp-content\/uploads\/collateral\/corporate-logos\/aaaa-logo.png 650w\" sizes=\"(max-width: 250px) 100vw, 250px\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/www.aana.com\/\" target=\"_blank\" rel=\"noopener noreferrer\"><img decoding=\"async\" class=\"alignnone wp-image-17208\" src=\"https:\/\/www.apsf.org\/wp-content\/uploads\/collateral\/corporate-logos\/aana-logo-2018-300x69.jpg\" alt=\"\u7f8e\u56fd\u62a4\u58eb\u9ebb\u9189\u5e08\u534f\u4f1a (AANA)\" width=\"250\" height=\"57\" srcset=\"https:\/\/www.apsf.org\/wp-content\/uploads\/collateral\/corporate-logos\/aana-logo-2018-300x69.jpg 300w, https:\/\/www.apsf.org\/wp-content\/uploads\/collateral\/corporate-logos\/aana-logo-2018-200x46.jpg 200w, https:\/\/www.apsf.org\/wp-content\/uploads\/collateral\/corporate-logos\/aana-logo-2018-768x176.jpg 768w, https:\/\/www.apsf.org\/wp-content\/uploads\/collateral\/corporate-logos\/aana-logo-2018-1024x234.jpg 1024w, https:\/\/www.apsf.org\/wp-content\/uploads\/collateral\/corporate-logos\/aana-logo-2018.jpg 1583w\" sizes=\"(max-width: 250px) 100vw, 250px\" \/><\/a><\/p>\n<\/div><strong><em>\u8054\u5408\u7acb\u573a\u58f0\u660e<\/em><\/strong><\/p>\n<p>\u7f8e\u56fd\u9ebb\u9189\u533b\u5e08\u534f\u4f1a (ASA)\u3001\u9ebb\u9189\u60a3\u8005\u5b89\u5168\u57fa\u91d1\u4f1a (APSF)\u3001\u7f8e\u56fd\u9ebb\u9189\u533b\u5e08\u52a9\u7406\u5b66\u4f1a (AAAA) \u548c\u7f8e\u56fd\u62a4\u58eb\u9ebb\u9189\u5e08\u534f\u4f1a (AANA) \u8ba4\u4e3a\u5728\u5236\u5b9a\u4e2a\u4eba\u9632\u62a4\u88c5\u5907 (PPE) \u76f8\u5173\u7684\u653f\u7b56\u65f6\uff0c\u9ebb\u9189\u4e13\u4e1a\u4eba\u58eb\u7684\u5b89\u5168\u81f3\u5173\u91cd\u8981\u3002\u5728\u7f8e\u56fd\u8fc5\u901f\u5347\u7ea7\u7684 COVID-19 \u75ab\u60c5\u671f\u95f4\uff0c\u7531\u4e8e\u5bc6\u5207\u63a5\u89e6\u60a3\u8005\u548c\u6c14\u9053\u7ba1\u7406\u9700\u8981\uff0c\u9ebb\u9189\u4e13\u4e1a\u4eba\u58eb\u5728\u6240\u6709\u8bca\u65ad\u3001\u6cbb\u7597\u548c\u5916\u79d1\u624b\u672f\u8fc7\u7a0b\u4e2d\u63a5\u89e6\u548c\u611f\u67d3\u65b0\u51a0\u75c5\u6bd2\u7684\u98ce\u9669\u8d8a\u6765\u8d8a\u5927\u3002<\/p>\n<p>\u8d8a\u6765\u8d8a\u591a\u7684\u7ecf\u9a8c\u8868\u660e\uff0c\u4ece\u63a5\u89e6 COVID-19 \u75c5\u6bd2\u5230\u51fa\u73b0\u75c7\u72b6\u4e4b\u524d\u53ef\u80fd\u6709 5 \u5929\u6216\u66f4\u957f\u65f6\u95f4\u7684\u6f5c\u4f0f\u671f\uff0c\u800c\u4e14\u90e8\u5206 COVID-19 \u9633\u6027\u60a3\u8005\u8981\u4e48\u65e0\u75c7\u72b6\uff0c\u8981\u4e48\u65e0\u660e\u663e\u75c7\u72b6\u3002\u5b9e\u9a8c\u5ba4\u51a0\u72b6\u75c5\u6bd2\u68c0\u6d4b\u76ee\u524d\u8fd8\u65e0\u6cd5\u5e7f\u6cdb\u800c\u5feb\u901f\u5730\u5f00\u5c55\u3002\u56e0\u6b64\uff0c\u5728\u4e34\u5e8a\u62a4\u7406\u73af\u5883\u4e0b\uff0c\u65e0\u6cd5\u786e\u5b9a\u8c01\u662f COVID-19 \u9633\u6027\u6216\u9634\u6027\u3002\u56e0\u6b64\uff0c\u6211\u4eec\u5efa\u8bae\u6240\u6709\u9ebb\u9189\u4e13\u4e1a\u4eba\u58eb\u5728\u60a3\u8005\u6c14\u9053\u5468\u8fb9\u5de5\u4f5c\u65f6\uff0c\u90fd\u5e94\u7a7f\u6234\u5408\u9002\u7684 PPE \u4ee5\u9632\u6b62\u6c14\u6eb6\u80f6\u4f20\u64ad\u3002<\/p>\n<p>\u7406\u60f3\u6761\u4ef6\u4e0b\uff0c\u9ebb\u9189\u4e13\u4e1a\u4eba\u58eb\u5e94\u9002\u5f53\u4f7f\u7528\u5bc6\u5408\u7684 N95 \u53e3\u7f69\u6216\u7535\u52a8\u7a7a\u6c14\u51c0\u5316\u547c\u5438\u5668 (PAPR)\u3002\u5bf9\u4e8e\u90a3\u4e9b\u6ca1\u6709\u8fdb\u884c N95 \u5bc6\u5408\u6027\u6d4b\u8bd5\u7684\u4eba\u5458\u3001\u9762\u90e8\u6709\u6bdb\u53d1\u7684\u4eba\u5458\uff0c\u6216\u8005\u6ca1\u6709\u901a\u8fc7 N95 \u5bc6\u5408\u6027\u6d4b\u8bd5\u7684\u4eba\u5458\uff0c\u5982\u6709\u6761\u4ef6\u5e94\u4f7f\u7528 PARR\u3002\u5916\u79d1\u53e3\u7f69\u53ef\u4ee5\u9632\u6b62 COVID-19 \u98de\u6cab\u7684\u4f20\u64ad\uff0c\u4f46\u4e0d\u80fd\u9632\u6b62\u6c14\u6eb6\u80f6\u5c0f\u9897\u7c92\u3002\u57fa\u4e8e\u4e0e COVID-19 \u7591\u4f3c\u6216\u786e\u8bca\u60a3\u8005\u7684\u8ddd\u79bb\u548c\u6e90\u5934\u63a7\u5236\u9700\u8981\uff08\u5373\u63a9\u853d\u6709\u75c7\u72b6\u7684\u60a3\u8005\uff09\uff0c\u7f8e\u56fd\u75be\u75c5\u63a7\u5236\u4e0e\u9884\u9632\u4e2d\u5fc3 (CDC) \u5236\u4f5c\u4e86\u4e00\u4efd\u8be6\u7ec6\u7684\u8868\u683c\uff08\u53c2\u8003\u6587\u732e 2\uff09\uff0c\u63cf\u8ff0\u4e86\u5916\u79d1\u53e3\u7f69\u3001N95 \u53e3\u7f69\u548c PAPR \u7684\u4f7f\u7528\u65b9\u6cd5\u3002<\/p>\n<p>\u5e94\u4f18\u5148\u4e3a\u6240\u6709\u4e34\u5e8a\u9ebb\u9189\u4eba\u5458\u53d1\u653e N95 \u53e3\u7f69\u6216\u63d0\u4f9b PAPR\u3002\u7136\u800c\uff0c\u5982\u679c\u76f8\u5173\u673a\u6784\u51fa\u73b0\u6216\u53ef\u80fd\u51fa\u73b0 N95 \u53e3\u7f69\u6216 PAPR \u77ed\u7f3a\u7684\u60c5\u51b5\uff0c\u5219\u5e94\u5236\u5b9a\u57fa\u4e8e\u5f53\u524d CDC \u5efa\u8bae\u7684\u4e34\u65f6\u7f13\u89e3\u8ba1\u5212\u3002\u8fd9\u4e9b\u8ba1\u5212\u5e94\u8be5\u5305\u62ec\u5bf9\u53ef\u80fd\u4ea7\u751f\u6c14\u6eb6\u80f6\u9897\u7c92\u7684\u60a3\u8005\u548c\u7a0b\u5e8f\u8fdb\u884c\u673a\u6784\u5ba1\u67e5\u548c\u4e2a\u6848\u5ba1\u67e5\uff0c\u4ee5\u53ca\u5bf9\u547c\u5438\u9053\u75c5\u539f\u4f53\u7684\u7279\u5f81\uff08\u4f8b\u5982\uff0c\u4f20\u64ad\u9014\u5f84\u3001\u793e\u533a\u4f20\u64ad\u3001\u8be5\u5730\u533a\u7684\u75be\u75c5\u6d41\u884c\u72b6\u51b5\u3001\u611f\u67d3\u653b\u51fb\u901f\u5ea6\u548c\u75be\u75c5\u7684\u4e25\u91cd\u7a0b\u5ea6\uff09\u548c\u5f53\u5730\u7684\u6761\u4ef6\uff08\u4f8b\u5982\uff0c\u4e00\u6b21\u6027 N95 \u53e3\u7f69\u53ef\u7528\u6570\u91cf\u3001\u76ee\u524d\u547c\u5438\u5668\u7684\u4f7f\u7528\u7387\uff0c\u4ee5\u53ca\u5b58\u50a8\u5176\u4ed6 PPE \u7684\u6210\u529f\u7b56\u7565\uff09\u8fdb\u884c\u8bc4\u4f30\u3002\u533b\u7597\u673a\u6784\u53ef\u80fd\u5e0c\u671b\u5728\u53d1\u73b0\u77ed\u7f3a\u4e4b\u524d\u5b9e\u65bd\u6269\u5927\u4f7f\u7528\u548c\/\u6216\u6709\u9650\u91cd\u590d\u4f7f\u7528\u7684\u505a\u6cd5\uff0c\u4ee5\u4fbf\u5728\u9700\u6c42\u9ad8\u5cf0\u671f\u4fdd\u969c\u5145\u8db3\u7684\u4f9b\u5e94\u3002N95 \u53e3\u7f69\u7684\u6269\u5927\u4f7f\u7528\u548c\/\u6216\u6709\u9650\u91cd\u590d\u4f7f\u7528\u5e94\u9075\u5faa CDC\uff08\u53c2\u8003\u6587\u732e 4\uff09\u548c\u673a\u6784\u6307\u5357\u3002<\/p>\n<p>\u9002\u7528 PPE \u7684\u6240\u6709\u7ec4\u4ef6\u90fd\u5e94\u4ed4\u7ec6\u5904\u7406\u3002\u9488\u5bf9\u4ea7\u751f\u6c14\u6eb6\u80f6\u7684\u8fc7\u7a0b\uff0c\u9664\u4e86\u4f7f\u7528 N95 \u53e3\u7f69\u6216 PAPR\uff08\u53c2\u8003\u6587\u732e 1\uff09\u8fdb\u884c\u6c14\u9053\u4fdd\u62a4\u5916\uff0c\u8fd8\u5e94\u5305\u62ec\u773c\u90e8\u4fdd\u62a4\uff08\u62a4\u76ee\u955c\u6216\u53ef\u4ee5\u8986\u76d6\u9762\u90e8\u524d\u65b9\u548c\u4fa7\u9762\u7684\u4e00\u6b21\u6027\u9762\u7f69\uff09\u3001\u9632\u62a4\u670d\u548c\u624b\u5957\u3002\u5728\u7a7f\u6234 PPE\uff08\u5305\u62ec\u624b\u5957\uff09\u524d\u540e\uff0c\u6709\u6548\u7684\u624b\u90e8\u536b\u751f\u662f\u975e\u5e38\u91cd\u8981\u7684\u3002\u5e94\u6309\u7167 CDC \u548c\u673a\u6784\u5efa\u8bae\u5efa\u7acb\u6b63\u786e\u7684\u7a7f\u8131\u7a0b\u5e8f\u3001\u5904\u7406\u53d7\u6c61\u67d3\u7684 PPE\u3001\u6e05\u6d01\u53d7\u6c61\u67d3\u4f46\u53ef\u91cd\u590d\u4f7f\u7528\u7684 PPE \u548c\u9ebb\u9189\u8bbe\u5907\u3002<\/p>\n<p>CDC \u5efa\u8bae\u91c7\u53d6\u7efc\u5408\u63aa\u65bd\uff0c\u5728\u4fdd\u62a4\u533b\u62a4\u4eba\u5458\u7684\u540c\u65f6\u8282\u7ea6\u4f9b\u5e94\uff0c\u5e76\u5728 N95 \u53e3\u7f69\u51fa\u73b0\u6216\u9884\u8ba1\u51fa\u73b0\u77ed\u7f3a\u7684\u60c5\u51b5\u4e0b\uff1a<\/p>\n<ul>\n<li>\u5b9e\u65bd\u5de5\u7a0b\u548c\u884c\u653f\u7ba1\u5236\uff0c\u5c3d\u91cf\u51cf\u5c11\u9700\u8981\u4f7f\u7528\u547c\u5438\u4fdd\u62a4\u88c5\u5907\u4eba\u5458\u7684\u6570\u91cf\u3002<\/li>\n<li>\u5728\u53ef\u884c\u7684\u60c5\u51b5\u4e0b\uff0c\u4f7f\u7528 N95 \u53e3\u7f69\u7684\u66ff\u4ee3\u54c1\uff08\u4f8b\u5982\uff0c\u5176\u4ed6\u7c7b\u522b\u7684\u8fc7\u6ee4\u9762\u7f69\u3001\u9762\u7f69\u5f0f\u7a7a\u6c14\u51c0\u5316\u547c\u5438\u5668\u548c PAPR\uff09\u3002\u6709\u5173\u8fd9\u4e9b\u547c\u5438\u5668\u7684\u66f4\u591a\u8be6\u60c5\uff0c\u8bf7\u53c2\u9605 CDC \u53d1\u5e03\u7684\u300a<a href=\"https:\/\/www.cdc.gov\/niosh\/docs\/2018-176\/default.html\" target=\"_blank\" rel=\"noopener noreferrer\">\u7a7a\u6c14\u51c0\u5316\u547c\u5438\u5668\u6307\u5357<\/a>\u300b\u3002<\/li>\n<li>\u5b9e\u65bd\u5141\u8bb8\u6269\u5927\u4f7f\u7528\u548c\/\u6216\u6709\u9650\u91cd\u590d\u4f7f\u7528 N95 \u53e3\u7f69\u7684\u5b9e\u8df5\u6d3b\u52a8\u3002<\/li>\n<li>\u5bf9\u4e8e COVID-19 \u63a5\u89e6\u98ce\u9669\u6700\u9ad8\u7684\u4eba\u5458\u548c\/\u6216\u9ad8\u5371\u9ebb\u9189\u4e13\u4e1a\u4eba\u58eb\uff08\u4f8b\u5982\uff0c\u6709\u57fa\u7840\u5065\u5eb7\u95ee\u9898\u6216\u5e74\u9f84\u8f83\u5927\u7684\u4eba\u58eb\uff09\uff0c\u5e94\u4f18\u5148\u4f7f\u7528 N95 \u53e3\u7f69\u3002<\/li>\n<li>\u7ecf\u7f8e\u56fd\u56fd\u5bb6\u804c\u4e1a\u5b89\u5168\u4e0e\u5065\u5eb7\u7814\u7a76\u6240 (NIOSH) \u6279\u51c6\u3001\u4f46\u76ee\u524d\u4e0d\u7b26\u5408\u7f8e\u56fd\u98df\u54c1\u548c\u836f\u7269\u7ba1\u7406\u5c40 (FDA) \u8981\u6c42\u7684\u4e3b\u8981\u7528\u4e8e\u5efa\u7b51\u548c\u5236\u9020\u4e1a\u7684\u53e3\u7f69\uff0c\u53ef\u6709\u6548\u5730\u4fdd\u62a4\u533b\u62a4\u4eba\u5458\u514d\u53d7\u75c5\u6bd2\u7684\u7a7a\u6c14\u4f20\u64ad\uff0c\u5305\u62ec COVID-19\u3002<\/li>\n<\/ul>\n<p><strong>\u53c2\u8003\u6587\u732e<\/strong><\/p>\n<ol>\n<li>\u7f8e\u56fd\u75be\u75c5\u63a7\u5236\u4e0e\u9884\u9632\u4e2d\u5fc3 (CDC)\u3002<a href=\"https:\/\/www.cdc.gov\/coronavirus\/2019-ncov\/infection-control\/control-recommendations.html\" target=\"_blank\" rel=\"noopener noreferrer\">\u9488\u5bf9\u533b\u7597\u573a\u6240\u4e2d 2019 \u65b0\u51a0\u80ba\u708e (COVID-19) \u7591\u4f3c\u548c\u786e\u8bca\u60a3\u8005\u7684\u4e34\u65f6\u611f\u67d3\u9884\u9632\u548c\u63a7\u5236\u5efa\u8bae<\/a>\u3002\u66f4\u65b0\u65e5\u671f\uff1a2020 \u5e74 3 \u6708 10 \u65e5\u3002\u8bbf\u95ee\u65e5\u671f\uff1a2020 \u5e74 3 \u6708 22 \u65e5\u3002<\/li>\n<li>\u7f8e\u56fd\u75be\u75c5\u63a7\u5236\u4e0e\u9884\u9632\u4e2d\u5fc3 (CDC)\u3002<a href=\"https:\/\/www.cdc.gov\/coronavirus\/2019-ncov\/hcp\/respirators-strategy\/crisis-alternate-strategies.html\" target=\"_blank\" rel=\"noopener noreferrer\">\u4f18\u5316 N95 \u547c\u5438\u5668\u4f9b\u5e94\u7684\u7b56\u7565\uff1a\u5371\u673a\/\u66ff\u4ee3\u7b56\u7565<\/a>\u3002\u66f4\u65b0\u65e5\u671f\uff1a2020 \u5e74 3 \u6708 17 \u65e5\u3002\u8bbf\u95ee\u65e5\u671f\uff1a2020 \u5e74 3 \u6708 22 \u65e5\u3002<\/li>\n<li>\u7f8e\u56fd\u75be\u75c5\u63a7\u5236\u4e0e\u9884\u9632\u4e2d\u5fc3 (CDC)\u3002<a href=\"https:\/\/www.cdc.gov\/coronavirus\/2019-ncov\/hcp\/checklist-n95-strategy.html\" target=\"_blank\" rel=\"noopener noreferrer\">\u533b\u7597\u673a\u6784\u68c0\u67e5\u6e05\u5355\uff1aCOVID-19 \u75ab\u60c5\u54cd\u5e94\u671f\u95f4\u4f18\u5316 N95 \u547c\u5438\u5668\u4f9b\u5e94\u7684\u7b56\u7565<\/a>\u3002\u66f4\u65b0\u65e5\u671f\uff1a2020 \u5e74 3 \u6708 5 \u65e5\u3002\u8bbf\u95ee\u65e5\u671f\uff1a2020 \u5e74 3 \u6708 22 \u65e5\u3002<\/li>\n<li>\u7f8e\u56fd\u75be\u75c5\u63a7\u5236\u4e0e\u9884\u9632\u4e2d\u5fc3 (CDC)\u3002<a href=\"https:\/\/www.cdc.gov\/niosh\/topics\/hcwcontrols\/recommendedguidanceextuse.html\" target=\"_blank\" rel=\"noopener noreferrer\">\u9488\u5bf9\u5728\u533b\u7597\u573a\u6240\u4e2d\u6269\u5927\u4f7f\u7528\u548c\u6709\u9650\u91cd\u590d\u4f7f\u7528 N95 \u8fc7\u6ee4\u9762\u7f69\u547c\u5438\u5668\u7684\u5efa\u8bae\u6027\u6307\u5357<\/a>\u3002\u66f4\u65b0\u65e5\u671f\uff1a2018 \u5e74 3 \u6708 28 \u65e5\u3002\u8bbf\u95ee\u65e5\u671f\uff1a2020 \u5e74 3 \u6708 22 \u65e5\u3002<\/li>\n<li>FDA \u65b0\u95fb\u7a3f\uff1a<a href=\"https:\/\/www.fda.gov\/news-events\/press-announcements\/coronavirus-covid-19-update-fda-and-cdc-take-action-increase-access-respirators-including-n95s\" target=\"_blank\" rel=\"noopener noreferrer\">\u51a0\u72b6\u75c5\u6bd2 (COVID-19) \u4fe1\u606f\u66f4\u65b0\uff1aFDA \u548c CDC \u91c7\u53d6\u884c\u52a8\uff0c\u589e\u52a0\u533b\u62a4\u4eba\u5458\u4f7f\u7528\u547c\u5438\u5668\uff08\u5305\u62ec N95\uff09\u7684\u673a\u4f1a<\/a>\u3002\u66f4\u65b0\u65e5\u671f\uff1a2020 \u5e74 3 \u6708 2 \u65e5\u3002\u8bbf\u95ee\u65e5\u671f\uff1a2020 \u5e74 3 \u6708 22 \u65e5\u3002<\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>\u7f8e\u56fd\u9ebb\u9189\u533b\u5e08\u534f\u4f1a (ASA)\u3001\u9ebb\u9189\u60a3\u8005\u5b89\u5168\u57fa\u91d1\u4f1a (APSF)\u3001\u7f8e\u56fd\u9ebb\u9189\u533b\u5e08\u52a9\u7406\u5b66\u4f1a (AAAA) \u548c\u7f8e\u56fd\u62a4\u58eb\u9ebb\u9189\u5e08\u534f\u4f1a (AANA) \u8ba4\u4e3a&#8230;<\/p>\n","protected":false},"author":1,"featured_media":60718,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":"","_members_access_role":[],"_members_access_error":""},"categories":[6738,1330],"tags":[],"class_list":["post-60715","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-covid-19","category-news-updates"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.6 (Yoast SEO v28.6) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>COVID-19 \u75ab\u60c5\u671f\u95f4\u9ebb\u9189\u4e13\u4e1a\u4eba\u58eb\u9632\u62a4\u88c5\u5907\u7684\u4f7f\u7528 - Anesthesia Patient Safety Foundation<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.apsf.org\/zh-hans\/news-updates\/covid-19-\u75ab\u60c5\u671f\u95f4\u9ebb\u9189\u4e13\u4e1a\u4eba\u58eb\u9632\u62a4\u88c5\u5907\u7684\u4f7f\u7528\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"COVID-19 \u75ab\u60c5\u671f\u95f4\u9ebb\u9189\u4e13\u4e1a\u4eba\u58eb\u9632\u62a4\u88c5\u5907\u7684\u4f7f\u7528\" \/>\n<meta property=\"og:description\" content=\"\u7f8e\u56fd\u9ebb\u9189\u533b\u5e08\u534f\u4f1a (ASA)\u3001\u9ebb\u9189\u60a3\u8005\u5b89\u5168\u57fa\u91d1\u4f1a (APSF)\u3001\u7f8e\u56fd\u9ebb\u9189\u533b\u5e08\u52a9\u7406\u5b66\u4f1a (AAAA) \u548c\u7f8e\u56fd\u62a4\u58eb\u9ebb\u9189\u5e08\u534f\u4f1a (AANA) \u8ba4\u4e3a...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.apsf.org\/zh-hans\/news-updates\/covid-19-\u75ab\u60c5\u671f\u95f4\u9ebb\u9189\u4e13\u4e1a\u4eba\u58eb\u9632\u62a4\u88c5\u5907\u7684\u4f7f\u7528\/\" \/>\n<meta property=\"og:site_name\" content=\"Anesthesia Patient Safety Foundation\" \/>\n<meta property=\"article:author\" content=\"#\" \/>\n<meta property=\"article:published_time\" content=\"2020-03-22T16:00:13+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-05-08T06:14:07+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.apsf.org\/wp-content\/uploads\/featured-images\/apsf-logos\/asa-apsf-aaaa-aana-statement-personal-protective-equipment.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"936\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"admin admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@#\" \/>\n<meta name=\"twitter:label1\" content=\"\u4f5c\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin admin\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.apsf.org\\\/zh-hans\\\/news-updates\\\/covid-19-%e7%96%ab%e6%83%85%e6%9c%9f%e9%97%b4%e9%ba%bb%e9%86%89%e4%b8%93%e4%b8%9a%e4%ba%ba%e5%a3%ab%e9%98%b2%e6%8a%a4%e8%a3%85%e5%a4%87%e7%9a%84%e4%bd%bf%e7%94%a8\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.apsf.org\\\/zh-hans\\\/news-updates\\\/covid-19-%e7%96%ab%e6%83%85%e6%9c%9f%e9%97%b4%e9%ba%bb%e9%86%89%e4%b8%93%e4%b8%9a%e4%ba%ba%e5%a3%ab%e9%98%b2%e6%8a%a4%e8%a3%85%e5%a4%87%e7%9a%84%e4%bd%bf%e7%94%a8\\\/\"},\"author\":{\"name\":\"admin admin\",\"@id\":\"https:\\\/\\\/www.apsf.org\\\/#\\\/schema\\\/person\\\/55ae256b76baa86d444aeba111724b86\"},\"headline\":\"COVID-19 \u75ab\u60c5\u671f\u95f4\u9ebb\u9189\u4e13\u4e1a\u4eba\u58eb\u9632\u62a4\u88c5\u5907\u7684\u4f7f\u7528\",\"datePublished\":\"2020-03-22T16:00:13+00:00\",\"dateModified\":\"2020-05-08T06:14:07+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.apsf.org\\\/zh-hans\\\/news-updates\\\/covid-19-%e7%96%ab%e6%83%85%e6%9c%9f%e9%97%b4%e9%ba%bb%e9%86%89%e4%b8%93%e4%b8%9a%e4%ba%ba%e5%a3%ab%e9%98%b2%e6%8a%a4%e8%a3%85%e5%a4%87%e7%9a%84%e4%bd%bf%e7%94%a8\\\/\"},\"wordCount\":67,\"image\":{\"@id\":\"https:\\\/\\\/www.apsf.org\\\/zh-hans\\\/news-updates\\\/covid-19-%e7%96%ab%e6%83%85%e6%9c%9f%e9%97%b4%e9%ba%bb%e9%86%89%e4%b8%93%e4%b8%9a%e4%ba%ba%e5%a3%ab%e9%98%b2%e6%8a%a4%e8%a3%85%e5%a4%87%e7%9a%84%e4%bd%bf%e7%94%a8\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.apsf.org\\\/wp-content\\\/uploads\\\/featured-images\\\/apsf-logos\\\/asa-apsf-aaaa-aana-statement-personal-protective-equipment.jpg\",\"articleSection\":[\"COVID-19\",\"News &amp; Updates\"],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.apsf.org\\\/zh-hans\\\/news-updates\\\/covid-19-%e7%96%ab%e6%83%85%e6%9c%9f%e9%97%b4%e9%ba%bb%e9%86%89%e4%b8%93%e4%b8%9a%e4%ba%ba%e5%a3%ab%e9%98%b2%e6%8a%a4%e8%a3%85%e5%a4%87%e7%9a%84%e4%bd%bf%e7%94%a8\\\/\",\"url\":\"https:\\\/\\\/www.apsf.org\\\/zh-hans\\\/news-updates\\\/covid-19-%e7%96%ab%e6%83%85%e6%9c%9f%e9%97%b4%e9%ba%bb%e9%86%89%e4%b8%93%e4%b8%9a%e4%ba%ba%e5%a3%ab%e9%98%b2%e6%8a%a4%e8%a3%85%e5%a4%87%e7%9a%84%e4%bd%bf%e7%94%a8\\\/\",\"name\":\"COVID-19 \u75ab\u60c5\u671f\u95f4\u9ebb\u9189\u4e13\u4e1a\u4eba\u58eb\u9632\u62a4\u88c5\u5907\u7684\u4f7f\u7528 - Anesthesia Patient Safety Foundation\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.apsf.org\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.apsf.org\\\/zh-hans\\\/news-updates\\\/covid-19-%e7%96%ab%e6%83%85%e6%9c%9f%e9%97%b4%e9%ba%bb%e9%86%89%e4%b8%93%e4%b8%9a%e4%ba%ba%e5%a3%ab%e9%98%b2%e6%8a%a4%e8%a3%85%e5%a4%87%e7%9a%84%e4%bd%bf%e7%94%a8\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.apsf.org\\\/zh-hans\\\/news-updates\\\/covid-19-%e7%96%ab%e6%83%85%e6%9c%9f%e9%97%b4%e9%ba%bb%e9%86%89%e4%b8%93%e4%b8%9a%e4%ba%ba%e5%a3%ab%e9%98%b2%e6%8a%a4%e8%a3%85%e5%a4%87%e7%9a%84%e4%bd%bf%e7%94%a8\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.apsf.org\\\/wp-content\\\/uploads\\\/featured-images\\\/apsf-logos\\\/asa-apsf-aaaa-aana-statement-personal-protective-equipment.jpg\",\"datePublished\":\"2020-03-22T16:00:13+00:00\",\"dateModified\":\"2020-05-08T06:14:07+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.apsf.org\\\/#\\\/schema\\\/person\\\/55ae256b76baa86d444aeba111724b86\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.apsf.org\\\/zh-hans\\\/news-updates\\\/covid-19-%e7%96%ab%e6%83%85%e6%9c%9f%e9%97%b4%e9%ba%bb%e9%86%89%e4%b8%93%e4%b8%9a%e4%ba%ba%e5%a3%ab%e9%98%b2%e6%8a%a4%e8%a3%85%e5%a4%87%e7%9a%84%e4%bd%bf%e7%94%a8\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.apsf.org\\\/zh-hans\\\/news-updates\\\/covid-19-%e7%96%ab%e6%83%85%e6%9c%9f%e9%97%b4%e9%ba%bb%e9%86%89%e4%b8%93%e4%b8%9a%e4%ba%ba%e5%a3%ab%e9%98%b2%e6%8a%a4%e8%a3%85%e5%a4%87%e7%9a%84%e4%bd%bf%e7%94%a8\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.apsf.org\\\/zh-hans\\\/news-updates\\\/covid-19-%e7%96%ab%e6%83%85%e6%9c%9f%e9%97%b4%e9%ba%bb%e9%86%89%e4%b8%93%e4%b8%9a%e4%ba%ba%e5%a3%ab%e9%98%b2%e6%8a%a4%e8%a3%85%e5%a4%87%e7%9a%84%e4%bd%bf%e7%94%a8\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.apsf.org\\\/wp-content\\\/uploads\\\/featured-images\\\/apsf-logos\\\/asa-apsf-aaaa-aana-statement-personal-protective-equipment.jpg\",\"contentUrl\":\"https:\\\/\\\/www.apsf.org\\\/wp-content\\\/uploads\\\/featured-images\\\/apsf-logos\\\/asa-apsf-aaaa-aana-statement-personal-protective-equipment.jpg\",\"width\":1200,\"height\":936},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.apsf.org\\\/zh-hans\\\/news-updates\\\/covid-19-%e7%96%ab%e6%83%85%e6%9c%9f%e9%97%b4%e9%ba%bb%e9%86%89%e4%b8%93%e4%b8%9a%e4%ba%ba%e5%a3%ab%e9%98%b2%e6%8a%a4%e8%a3%85%e5%a4%87%e7%9a%84%e4%bd%bf%e7%94%a8\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.apsf.org\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"COVID-19 \u75ab\u60c5\u671f\u95f4\u9ebb\u9189\u4e13\u4e1a\u4eba\u58eb\u9632\u62a4\u88c5\u5907\u7684\u4f7f\u7528\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.apsf.org\\\/#website\",\"url\":\"https:\\\/\\\/www.apsf.org\\\/\",\"name\":\"Anesthesia Patient Safety Foundation\",\"description\":\"That no one shall be harmed by anesthesia care.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.apsf.org\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.apsf.org\\\/#\\\/schema\\\/person\\\/55ae256b76baa86d444aeba111724b86\",\"name\":\"admin admin\",\"sameAs\":[\"#\",\"https:\\\/\\\/x.com\\\/#\"],\"url\":\"https:\\\/\\\/www.apsf.org\\\/zh-hans\\\/profile\\\/admin-admin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"COVID-19 \u75ab\u60c5\u671f\u95f4\u9ebb\u9189\u4e13\u4e1a\u4eba\u58eb\u9632\u62a4\u88c5\u5907\u7684\u4f7f\u7528 - Anesthesia Patient Safety Foundation","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.apsf.org\/zh-hans\/news-updates\/covid-19-\u75ab\u60c5\u671f\u95f4\u9ebb\u9189\u4e13\u4e1a\u4eba\u58eb\u9632\u62a4\u88c5\u5907\u7684\u4f7f\u7528\/","og_locale":"zh_CN","og_type":"article","og_title":"COVID-19 \u75ab\u60c5\u671f\u95f4\u9ebb\u9189\u4e13\u4e1a\u4eba\u58eb\u9632\u62a4\u88c5\u5907\u7684\u4f7f\u7528","og_description":"\u7f8e\u56fd\u9ebb\u9189\u533b\u5e08\u534f\u4f1a (ASA)\u3001\u9ebb\u9189\u60a3\u8005\u5b89\u5168\u57fa\u91d1\u4f1a (APSF)\u3001\u7f8e\u56fd\u9ebb\u9189\u533b\u5e08\u52a9\u7406\u5b66\u4f1a (AAAA) \u548c\u7f8e\u56fd\u62a4\u58eb\u9ebb\u9189\u5e08\u534f\u4f1a (AANA) \u8ba4\u4e3a...","og_url":"https:\/\/www.apsf.org\/zh-hans\/news-updates\/covid-19-\u75ab\u60c5\u671f\u95f4\u9ebb\u9189\u4e13\u4e1a\u4eba\u58eb\u9632\u62a4\u88c5\u5907\u7684\u4f7f\u7528\/","og_site_name":"Anesthesia Patient Safety Foundation","article_author":"#","article_published_time":"2020-03-22T16:00:13+00:00","article_modified_time":"2020-05-08T06:14:07+00:00","og_image":[{"width":1200,"height":936,"url":"https:\/\/www.apsf.org\/wp-content\/uploads\/featured-images\/apsf-logos\/asa-apsf-aaaa-aana-statement-personal-protective-equipment.jpg","type":"image\/jpeg"}],"author":"admin admin","twitter_card":"summary_large_image","twitter_creator":"@#","twitter_misc":{"\u4f5c\u8005":"admin admin"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.apsf.org\/zh-hans\/news-updates\/covid-19-%e7%96%ab%e6%83%85%e6%9c%9f%e9%97%b4%e9%ba%bb%e9%86%89%e4%b8%93%e4%b8%9a%e4%ba%ba%e5%a3%ab%e9%98%b2%e6%8a%a4%e8%a3%85%e5%a4%87%e7%9a%84%e4%bd%bf%e7%94%a8\/#article","isPartOf":{"@id":"https:\/\/www.apsf.org\/zh-hans\/news-updates\/covid-19-%e7%96%ab%e6%83%85%e6%9c%9f%e9%97%b4%e9%ba%bb%e9%86%89%e4%b8%93%e4%b8%9a%e4%ba%ba%e5%a3%ab%e9%98%b2%e6%8a%a4%e8%a3%85%e5%a4%87%e7%9a%84%e4%bd%bf%e7%94%a8\/"},"author":{"name":"admin admin","@id":"https:\/\/www.apsf.org\/#\/schema\/person\/55ae256b76baa86d444aeba111724b86"},"headline":"COVID-19 \u75ab\u60c5\u671f\u95f4\u9ebb\u9189\u4e13\u4e1a\u4eba\u58eb\u9632\u62a4\u88c5\u5907\u7684\u4f7f\u7528","datePublished":"2020-03-22T16:00:13+00:00","dateModified":"2020-05-08T06:14:07+00:00","mainEntityOfPage":{"@id":"https:\/\/www.apsf.org\/zh-hans\/news-updates\/covid-19-%e7%96%ab%e6%83%85%e6%9c%9f%e9%97%b4%e9%ba%bb%e9%86%89%e4%b8%93%e4%b8%9a%e4%ba%ba%e5%a3%ab%e9%98%b2%e6%8a%a4%e8%a3%85%e5%a4%87%e7%9a%84%e4%bd%bf%e7%94%a8\/"},"wordCount":67,"image":{"@id":"https:\/\/www.apsf.org\/zh-hans\/news-updates\/covid-19-%e7%96%ab%e6%83%85%e6%9c%9f%e9%97%b4%e9%ba%bb%e9%86%89%e4%b8%93%e4%b8%9a%e4%ba%ba%e5%a3%ab%e9%98%b2%e6%8a%a4%e8%a3%85%e5%a4%87%e7%9a%84%e4%bd%bf%e7%94%a8\/#primaryimage"},"thumbnailUrl":"https:\/\/www.apsf.org\/wp-content\/uploads\/featured-images\/apsf-logos\/asa-apsf-aaaa-aana-statement-personal-protective-equipment.jpg","articleSection":["COVID-19","News &amp; Updates"],"inLanguage":"zh-Hans"},{"@type":"WebPage","@id":"https:\/\/www.apsf.org\/zh-hans\/news-updates\/covid-19-%e7%96%ab%e6%83%85%e6%9c%9f%e9%97%b4%e9%ba%bb%e9%86%89%e4%b8%93%e4%b8%9a%e4%ba%ba%e5%a3%ab%e9%98%b2%e6%8a%a4%e8%a3%85%e5%a4%87%e7%9a%84%e4%bd%bf%e7%94%a8\/","url":"https:\/\/www.apsf.org\/zh-hans\/news-updates\/covid-19-%e7%96%ab%e6%83%85%e6%9c%9f%e9%97%b4%e9%ba%bb%e9%86%89%e4%b8%93%e4%b8%9a%e4%ba%ba%e5%a3%ab%e9%98%b2%e6%8a%a4%e8%a3%85%e5%a4%87%e7%9a%84%e4%bd%bf%e7%94%a8\/","name":"COVID-19 \u75ab\u60c5\u671f\u95f4\u9ebb\u9189\u4e13\u4e1a\u4eba\u58eb\u9632\u62a4\u88c5\u5907\u7684\u4f7f\u7528 - Anesthesia Patient Safety Foundation","isPartOf":{"@id":"https:\/\/www.apsf.org\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.apsf.org\/zh-hans\/news-updates\/covid-19-%e7%96%ab%e6%83%85%e6%9c%9f%e9%97%b4%e9%ba%bb%e9%86%89%e4%b8%93%e4%b8%9a%e4%ba%ba%e5%a3%ab%e9%98%b2%e6%8a%a4%e8%a3%85%e5%a4%87%e7%9a%84%e4%bd%bf%e7%94%a8\/#primaryimage"},"image":{"@id":"https:\/\/www.apsf.org\/zh-hans\/news-updates\/covid-19-%e7%96%ab%e6%83%85%e6%9c%9f%e9%97%b4%e9%ba%bb%e9%86%89%e4%b8%93%e4%b8%9a%e4%ba%ba%e5%a3%ab%e9%98%b2%e6%8a%a4%e8%a3%85%e5%a4%87%e7%9a%84%e4%bd%bf%e7%94%a8\/#primaryimage"},"thumbnailUrl":"https:\/\/www.apsf.org\/wp-content\/uploads\/featured-images\/apsf-logos\/asa-apsf-aaaa-aana-statement-personal-protective-equipment.jpg","datePublished":"2020-03-22T16:00:13+00:00","dateModified":"2020-05-08T06:14:07+00:00","author":{"@id":"https:\/\/www.apsf.org\/#\/schema\/person\/55ae256b76baa86d444aeba111724b86"},"breadcrumb":{"@id":"https:\/\/www.apsf.org\/zh-hans\/news-updates\/covid-19-%e7%96%ab%e6%83%85%e6%9c%9f%e9%97%b4%e9%ba%bb%e9%86%89%e4%b8%93%e4%b8%9a%e4%ba%ba%e5%a3%ab%e9%98%b2%e6%8a%a4%e8%a3%85%e5%a4%87%e7%9a%84%e4%bd%bf%e7%94%a8\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.apsf.org\/zh-hans\/news-updates\/covid-19-%e7%96%ab%e6%83%85%e6%9c%9f%e9%97%b4%e9%ba%bb%e9%86%89%e4%b8%93%e4%b8%9a%e4%ba%ba%e5%a3%ab%e9%98%b2%e6%8a%a4%e8%a3%85%e5%a4%87%e7%9a%84%e4%bd%bf%e7%94%a8\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.apsf.org\/zh-hans\/news-updates\/covid-19-%e7%96%ab%e6%83%85%e6%9c%9f%e9%97%b4%e9%ba%bb%e9%86%89%e4%b8%93%e4%b8%9a%e4%ba%ba%e5%a3%ab%e9%98%b2%e6%8a%a4%e8%a3%85%e5%a4%87%e7%9a%84%e4%bd%bf%e7%94%a8\/#primaryimage","url":"https:\/\/www.apsf.org\/wp-content\/uploads\/featured-images\/apsf-logos\/asa-apsf-aaaa-aana-statement-personal-protective-equipment.jpg","contentUrl":"https:\/\/www.apsf.org\/wp-content\/uploads\/featured-images\/apsf-logos\/asa-apsf-aaaa-aana-statement-personal-protective-equipment.jpg","width":1200,"height":936},{"@type":"BreadcrumbList","@id":"https:\/\/www.apsf.org\/zh-hans\/news-updates\/covid-19-%e7%96%ab%e6%83%85%e6%9c%9f%e9%97%b4%e9%ba%bb%e9%86%89%e4%b8%93%e4%b8%9a%e4%ba%ba%e5%a3%ab%e9%98%b2%e6%8a%a4%e8%a3%85%e5%a4%87%e7%9a%84%e4%bd%bf%e7%94%a8\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.apsf.org\/"},{"@type":"ListItem","position":2,"name":"COVID-19 \u75ab\u60c5\u671f\u95f4\u9ebb\u9189\u4e13\u4e1a\u4eba\u58eb\u9632\u62a4\u88c5\u5907\u7684\u4f7f\u7528"}]},{"@type":"WebSite","@id":"https:\/\/www.apsf.org\/#website","url":"https:\/\/www.apsf.org\/","name":"Anesthesia Patient Safety Foundation","description":"That no one shall be harmed by anesthesia care.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.apsf.org\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/www.apsf.org\/#\/schema\/person\/55ae256b76baa86d444aeba111724b86","name":"admin admin","sameAs":["#","https:\/\/x.com\/#"],"url":"https:\/\/www.apsf.org\/zh-hans\/profile\/admin-admin\/"}]}},"_links":{"self":[{"href":"https:\/\/www.apsf.org\/zh-hans\/wp-json\/wp\/v2\/posts\/60715","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.apsf.org\/zh-hans\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.apsf.org\/zh-hans\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.apsf.org\/zh-hans\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.apsf.org\/zh-hans\/wp-json\/wp\/v2\/comments?post=60715"}],"version-history":[{"count":1,"href":"https:\/\/www.apsf.org\/zh-hans\/wp-json\/wp\/v2\/posts\/60715\/revisions"}],"predecessor-version":[{"id":60717,"href":"https:\/\/www.apsf.org\/zh-hans\/wp-json\/wp\/v2\/posts\/60715\/revisions\/60717"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.apsf.org\/zh-hans\/wp-json\/wp\/v2\/media\/60718"}],"wp:attachment":[{"href":"https:\/\/www.apsf.org\/zh-hans\/wp-json\/wp\/v2\/media?parent=60715"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.apsf.org\/zh-hans\/wp-json\/wp\/v2\/categories?post=60715"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.apsf.org\/zh-hans\/wp-json\/wp\/v2\/tags?post=60715"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}